Concrete Vc
31.37 kip
Stirrup Vs
0 kip
φVn
23.53 kip
Spacing max
18.5 in
Anatomy Diagrammatic scale
Parameter-linked shear drawing. Diagrammatic scale.
STIRRUP ELEVATION d bw 14 in Av = 0 Vs 0 kip
Screening Within screening limits
Shear utilization 34%
Table 22.5.5.1(c) 66% below the threshold
Shear strength Vu ≤ φ(Vc + Vs, credited)
Within limit Diagonal compression Required Vs ≤ 8√f′c bw d
Within limit Minimum stirrup area Av ≥ Av,min when Vu > φλ√f′c bw d
Within limit Stirrup spacing Longitudinal spacing ≤ smax
Within limit
Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.
Calculation readout Quantity Value
Concrete shear Vc 31.37 kip Provided stirrup Vs 0 kip Design shear φVn 23.53 kip Maximum stirrup spacing 18.5 in Minimum stirrup area Av,min 0.0933 in² Minimum steel demand trigger 24.57 kip Required stirrup Vs 0 kip Diagonal compression Vs cap 262.09 kip Size effect λs (applied) 0.652 Longitudinal ratio ρw 0.618 % Axial stress contribution 0 psi Transverse yield used 60 ksi
Share link
Reset defaults
JSON
CSV
SVG
PNG ×2
Print A4
Starting inputs
Web width bw 14 in
Overall depth h 42 in
Effective depth d 37 in
Longitudinal steel As 3.2 in²
Factored shear Vu 8 kip
Leg area Av 0 in²
Calculated result
Concrete shear Vc 31.37 kip
Provided stirrup Vs 0 kip
Design shear φVn 23.53 kip
Maximum stirrup spacing 18.5 in Even where stirrups are not required by the demand trigger, the concrete equation uses the size reduction.
Preset screening · Table 22.5.5.1(c) · Within limits
Use Table 22.5.5.1(a) when Av reaches Av,min. Below Av,min, use (c) with λs and ρw = As/(bw d). Cap the axial compression stress term at 0.05f′c and floor Vc at zero. Limit √f′c to 100 for the concrete term unless minimum web steel is present. Take Vs = Av fyt d/s, limiting fyt to 60 ksi for deformed-bar stirrups. Calculate φVn with φ = 0.75 and cap the credited Vs at 8√f′c bw d. Check the required Vs against that section limit. Use max(0.75√f′c, 50)bw s/fyt for Av,min and apply the ordinary-beam trigger Vu > φλ√f′c bw d. Select the spacing band from required Vs per Table 9.7.6.2.2: min(d/2, 24 in) up to 4√f′c bw d, then min(d/4, 12 in).
RebarStructLab • ACI 318-19 • US
§9.6 / §9.7 / §22.5
Deep lightly loaded web without stirrups
Vertical stirrups · rectangular web · Within screening limits
Inputs
Web width bw 14 in
Overall depth h 42 in
Effective depth d 37 in
Longitudinal steel As 3.2 in²
Axial Nu (+ compression) 0 kip
Factored shear Vu 8 kip
Concrete strength f′c 4,000 psi
Lightweight factor λ 1
Leg area Av 0 in²
Stirrup spacing s 8 in
Transverse yield fyt 60 ksi
Calculated values
Concrete shear Vc 31.37 kip
Provided stirrup Vs 0 kip
Design shear φVn 23.53 kip
Maximum stirrup spacing 18.5 in
Minimum stirrup area Av,min 0.0933 in²
Minimum steel demand trigger 24.57 kip
Required stirrup Vs 0 kip
Diagonal compression Vs cap 262.09 kip
Size effect λs (applied) 0.652
Longitudinal ratio ρw 0.618 %
Axial stress contribution 0 psi
Transverse yield used 60 ksi
Parameter-linked shear drawing. Diagrammatic scale.
STIRRUP ELEVATION d bw 14 in Av = 0 Vs 0 kip
Screening
Table 22.5.5.1(c) · Shear utilization 34%
Shear strength · Within limitDiagonal compression · Within limitMinimum stirrup area · Within limitStirrup spacing · Within limit
Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.