ACI 318-19 §25.3 / §25.4 / §25.5

Class B tension lap for No. 8 bars

A Grade 60 bar uses a Class B tension splice over an available 38 in.

Edit inputs ↓

Inputs

Editable example

Bar & bond
Available geometry
Straight ℓd 28.46in
Hook ℓdh 18.69in
Class B lap 37in
Confinement 2.5 
AnatomyDiagrammatic scale
Parameter-linked development drawing. Diagrammatic scale. CLASS B TENSION LAPRequired overlapdb 1 inNeed 37 inHave 38 in

Screening

Within screening limits
Required / available length97.4%
Class B tension splice2.6% below the threshold
  • Available embedmentAvailable length ≥ required length for the selected detail
    Within limit

Ordinary nonseismic tension details. Available length is measured along the straight bar or to the outside of the hook. Check minimum cover, bend fabrication and confinement at discontinuous ends separately.

Calculation readout
QuantityValue
Straight development ℓd28.46 in
Hook development ℓdh18.69 in
Class B with 1.3 × floored ℓd37 in
Confinement (cᵦ + Ktr)/db2.5
Nominal bar diameter db1 in
Spacing/cover term cᵦ2.5 in
Selected required length37 in
Class B minimum per §25.5.237 in
Minimum inside bend diameter6 in
90° straight tail12 in
180° straight tail4 in
Top cast ψt1
Epoxy ψe (straight)1
Size ψs1
Grade ψg1
Hook confinement ψr1
Hook location ψo1.25
Hook concrete ψc0.867

Original example

Worked solution

Default calculator ↗

Starting inputs

Bar size
#8
Detail to screen
Class B splice
Available length
38 in

Calculated result

Straight development ℓd
28.46 in
Hook development ℓdh
18.69 in
Class B minimum per §25.5.2
37 in
Confinement (cᵦ + Ktr)/db
2.5

Read the straight length first, then apply 1.3 for the lap. This case is above the straight length floor.

Preset screening · Class B tension splice · Within limits

How the check works

Code basis ↗
  1. Use cᵦ = min(clear cover + db/2, bar spacing/2). Cap (cᵦ + Ktr)/db at 2.5, ψtψe at 1.7 and √f′c at 100. Calculate ℓd from Eq. (25.4.2.4a) with a 12 in floor.
  2. Check a Class B splice with the §25.5.2 minimum: multiply the unfloored ℓd by 1.3 and then apply the 12 in floor. The detail readout also shows 1.3 times the floored straight length for comparison.
  3. Use Eq. (25.4.3.1) and its own hook factors for ℓdh, subject to 8db and 6 in minima. A 90° hook needs a 12db tail; a 180° hook needs max(4db, 2.5 in). Check the outer bend envelope and tail run.