Available embedmentAvailable length ≥ required length for the selected detail
Within limit
Hook tail runTail ≥ max(4db, 2.5 in)
Outside limit
Bend envelopeClear envelope ≥ minimum inside bend diameter + 2db
Within limit
Ordinary nonseismic tension details. Available length is measured along the straight bar or to the outside of the hook. Check minimum cover, bend fabrication and confinement at discontinuous ends separately.
Use cᵦ = min(clear cover + db/2, bar spacing/2). Cap (cᵦ + Ktr)/db at 2.5, ψtψe at 1.7 and √f′c at 100. Calculate ℓd from Eq. (25.4.2.4a) with a 12 in floor.
Check a Class B splice with the §25.5.2 minimum: multiply the unfloored ℓd by 1.3 and then apply the 12 in floor. The detail readout also shows 1.3 times the floored straight length for comparison.
Use Eq. (25.4.3.1) and its own hook factors for ℓdh, subject to 8db and 6 in minima. A 90° hook needs a 12db tail; a 180° hook needs max(4db, 2.5 in). Check the outer bend envelope and tail run.
Deformed tension bars · standard hooks · Limit exceeded
Inputs
Bar size
#11
Concrete strength f′c
5,000 psi
Steel grade fy
80 ksi
Concrete weight
Normalweight (λ = 1.00)
Top-cast bar
No
Epoxy coated
No
Minimum clear cover
3.5 in
Bar spacing c/c
10 in
Confinement index Ktr
0 in
Detail to screen
180° standard hook
Available length
45 in
Hook inside column core
No
Hook confinement Ath/Ahs
0
Clear hook tail run
4 in
Clear bend envelope
15 in
Calculated values
Straight development ℓd
55.04 in
Hook development ℓdh
40.18 in
Class B with 1.3 × floored ℓd
71.55 in
Confinement (cᵦ + Ktr)/db
2.5
Nominal bar diameter db
1.41 in
Spacing/cover term cᵦ
4.205 in
Selected required length
40.18 in
Class B minimum per §25.5.2
71.55 in
Minimum inside bend diameter
11.28 in
90° straight tail
16.92 in
180° straight tail
5.64 in
Top cast ψt
1
Epoxy ψe (straight)
1
Size ψs
1
Grade ψg
1.15
Hook confinement ψr
1
Hook location ψo
1.25
Hook concrete ψc
0.933
Screening
180° standard hook · Required / available length 89.3%
Available embedment · Within limit
Hook tail run · Outside limit
Bend envelope · Within limit
Ordinary nonseismic tension details. Available length is measured along the straight bar or to the outside of the hook. Check minimum cover, bend fabrication and confinement at discontinuous ends separately.