ACI 318-19 §25.3 / §25.4 / §25.5

Straight length floor in high-strength concrete

A No. 3 Grade 40 bar in 12,000 psi concrete reaches the straight development length floor.

Edit inputs ↓

Inputs

Editable example

Bar & bond
Available geometry
Straight ℓd 12in
Hook ℓdh 6in
Class B lap 12in
Confinement 2.5 
AnatomyDiagrammatic scale
Parameter-linked development drawing. Diagrammatic scale. STRAIGHT BAR DEVELOPMENTRequired embedmentdb 0.375 inNeed 12 inHave 12 in

Screening

Within screening limits
Required / available length100%
Straight tension barAt the 100% threshold
  • Available embedmentAvailable length ≥ required length for the selected detail
    Within limit

Ordinary nonseismic tension details. Available length is measured along the straight bar or to the outside of the hook. Check minimum cover, bend fabrication and confinement at discontinuous ends separately.

Calculation readout
QuantityValue
Straight development ℓd12 in
Hook development ℓdh6 in
Class B with 1.3 × floored ℓd15.6 in
Confinement (cᵦ + Ktr)/db2.5
Nominal bar diameter db0.375 in
Spacing/cover term cᵦ2.188 in
Selected required length12 in
Class B minimum per §25.5.212 in
Minimum inside bend diameter2.25 in
90° straight tail4.5 in
180° straight tail2.5 in
Top cast ψt1
Epoxy ψe (straight)1
Size ψs0.8
Grade ψg1
Hook confinement ψr1
Hook location ψo1.25
Hook concrete ψc1

Original example

Worked solution

Default calculator ↗

Starting inputs

Bar size
#3
Concrete strength f′c
12,000 psi
Steel grade fy
40 ksi
Available length
12 in

Calculated result

Straight development ℓd
12 in
Hook development ℓdh
6 in
Class B minimum per §25.5.2
12 in
Confinement (cᵦ + Ktr)/db
2.5

Limit the square-root term to 100 before calculating length. The 12 in floor still controls the straight result.

Preset screening · Straight tension bar · Within limits

How the check works

Code basis ↗
  1. Use cᵦ = min(clear cover + db/2, bar spacing/2). Cap (cᵦ + Ktr)/db at 2.5, ψtψe at 1.7 and √f′c at 100. Calculate ℓd from Eq. (25.4.2.4a) with a 12 in floor.
  2. Check a Class B splice with the §25.5.2 minimum: multiply the unfloored ℓd by 1.3 and then apply the 12 in floor. The detail readout also shows 1.3 times the floored straight length for comparison.
  3. Use Eq. (25.4.3.1) and its own hook factors for ℓdh, subject to 8db and 6 in minima. A 90° hook needs a 12db tail; a 180° hook needs max(4db, 2.5 in). Check the outer bend envelope and tail run.