ACI 318-19 §9.6 / §9.7 / §22.5

Deep lightly loaded web without stirrups

A larger web carries light shear with Av = 0, making the longitudinal ratio and depth reduction explicit.

Edit inputs ↓

Inputs

Editable example

Section & loads
Materials & stirrups
Concrete Vc 31.37kip
Stirrup Vs 0kip
φVn 23.53kip
Spacing max 18.5in
AnatomyDiagrammatic scale
Parameter-linked shear drawing. Diagrammatic scale. STIRRUP ELEVATIONdbw 14 inAv = 0Vs 0 kip

Screening

Within screening limits
Shear utilization34%
Table 22.5.5.1(c)66% below the threshold
  • Shear strengthVu ≤ φ(Vc + Vs, credited)
    Within limit
  • Diagonal compressionRequired Vs ≤ 8√f′c bw d
    Within limit
  • Minimum stirrup areaAv ≥ Av,min when Vu > φλ√f′c bw d
    Within limit
  • Stirrup spacingLongitudinal spacing ≤ smax
    Within limit

Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.

Calculation readout
QuantityValue
Concrete shear Vc31.37 kip
Provided stirrup Vs0 kip
Design shear φVn23.53 kip
Maximum stirrup spacing18.5 in
Minimum stirrup area Av,min0.0933 in²
Minimum steel demand trigger24.57 kip
Required stirrup Vs0 kip
Diagonal compression Vs cap262.09 kip
Size effect λs (applied)0.652
Longitudinal ratio ρw0.618 %
Axial stress contribution0 psi
Transverse yield used60 ksi

Original example

Worked solution

Default calculator ↗

Starting inputs

Web width bw
14 in
Overall depth h
42 in
Effective depth d
37 in
Longitudinal steel As
3.2 in²
Factored shear Vu
8 kip
Leg area Av
0 in²

Calculated result

Concrete shear Vc
31.37 kip
Provided stirrup Vs
0 kip
Design shear φVn
23.53 kip
Maximum stirrup spacing
18.5 in

Even where stirrups are not required by the demand trigger, the concrete equation uses the size reduction.

Preset screening · Table 22.5.5.1(c) · Within limits

How the check works

Code basis ↗
  1. Use Table 22.5.5.1(a) when Av reaches Av,min. Below Av,min, use (c) with λs and ρw = As/(bw d). Cap the axial compression stress term at 0.05f′c and floor Vc at zero. Limit √f′c to 100 for the concrete term unless minimum web steel is present.
  2. Take Vs = Av fyt d/s, limiting fyt to 60 ksi for deformed-bar stirrups. Calculate φVn with φ = 0.75 and cap the credited Vs at 8√f′c bw d. Check the required Vs against that section limit.
  3. Use max(0.75√f′c, 50)bw s/fyt for Av,min and apply the ordinary-beam trigger Vu > φλ√f′c bw d. Select the spacing band from required Vs per Table 9.7.6.2.2: min(d/2, 24 in) up to 4√f′c bw d, then min(d/4, 12 in).