ACI 318-19 §9.3 / §9.6 / §22.2

Doubly reinforced beam with top steel

A deeper rectangular section has steel near both faces to resist a 390 kip·ft factored moment.

Edit inputs ↓

Inputs

Editable example

Section
Reinforcement & demand
φMn 448.56kip·ft
Block a 4.22in
Axis c 5.27in
Strain εt 10,366με
AnatomyDiagrammatic scale
Parameter-linked flexure drawing. Diagrammatic scale. RC SECTIONSTRAINWHITNEY BLOCKhb 12 ind 23.5 ina 4.22 in

Screening

Within screening limits
Moment utilization86.9%
Tension controlled13.1% below the threshold
  • Bending strengthMu ≤ φMn
    Within limit
  • Minimum tension steelAs ≥ As,min per §9.6.1.2
    Within limit
  • Tension controlεt ≥ εty + 0.003 per §9.3.3.1
    Within limit

Positive pure bending of a nonprestressed rectangular beam. The calculation excludes combined axial force, shear, anchorage and the minimum-steel exception in §9.6.1.3.

Calculation readout
QuantityValue
Design moment φMn448.56 kip·ft
Stress block depth a4.22 in
Neutral axis depth c5.27 in
Net tensile strain εt10,366 με
Strength factor φ0.9
Whitney factor β₁0.8
Tension-controlled limit5,069 με
Nominal moment Mn498.4 kip·ft
Minimum tension steel As,min0.997 in²
Concrete compression Cc215.21 kip
Top steel force Cs,net65.59 kip
Tension steel force Ts280.8 kip

Original example

Worked solution

Default calculator ↗

Starting inputs

Overall depth h
26 in
Tension steel depth d
23.5 in
Tension steel As
4.68 in²
Top steel As′
1.58 in²
Concrete strength f′c
5,000 psi
Factored moment Mu
390 kip·ft

Calculated result

Design moment φMn
448.56 kip·ft
Stress block depth a
4.22 in
Neutral axis depth c
5.27 in
Net tensile strain εt
10,366 με

Compare the top-steel force and the Whitney compression resultant. The top reinforcement is calculated from strain, with displaced concrete deducted inside the block.

Preset screening · Tension controlled · Within limits

How the check works

Code basis ↗
  1. β₁ drops linearly from 0.85 at 4,000 psi by 0.05 per additional 1,000 psi, with a 0.65 floor at 8,000 psi. The two strength thresholds display as approximately 27.6 and 55.2 MPa.
  2. Solve force equilibrium using εcu = 0.003, a = β₁c and elastic-perfectly plastic steel. Deduct 0.85f′c from the stress of top steel inside the concrete block. Sum moments of the compression forces about the tension steel.
  3. Use φ = 0.65 below εty and interpolate to 0.90 at εty + 0.003, with εty = fy/Es. Check tension control and As,min = max(3√f′c, 200)bw d / min(fy, 80 ksi).