Positive pure bending of a nonprestressed rectangular beam. The calculation excludes combined axial force, shear, anchorage and the minimum-steel exception in §9.6.1.3.
Compare the top-steel force and the Whitney compression resultant. The top reinforcement is calculated from strain, with displaced concrete deducted inside the block.
Preset screening · Tension controlled · Within limits
β₁ drops linearly from 0.85 at 4,000 psi by 0.05 per additional 1,000 psi, with a 0.65 floor at 8,000 psi. The two strength thresholds display as approximately 27.6 and 55.2 MPa.
Solve force equilibrium using εcu = 0.003, a = β₁c and elastic-perfectly plastic steel. Deduct 0.85f′c from the stress of top steel inside the concrete block. Sum moments of the compression forces about the tension steel.
Use φ = 0.65 below εty and interpolate to 0.90 at εty + 0.003, with εty = fy/Es. Check tension control and As,min = max(3√f′c, 200)bw d / min(fy, 80 ksi).
Rectangular section · pure bending · Within screening limits
Inputs
Section width b
12 in
Overall depth h
26 in
Tension steel depth d
23.5 in
Top steel depth d′
2.5 in
Tension steel As
4.68 in²
Top steel As′
1.58 in²
Concrete strength f′c
5,000 psi
Steel yield strength fy
60 ksi
Factored moment Mu
390 kip·ft
Calculated values
Design moment φMn
448.56 kip·ft
Stress block depth a
4.22 in
Neutral axis depth c
5.27 in
Net tensile strain εt
10,366 με
Strength factor φ
0.9
Whitney factor β₁
0.8
Tension-controlled limit
5,069 με
Nominal moment Mn
498.4 kip·ft
Minimum tension steel As,min
0.997 in²
Concrete compression Cc
215.21 kip
Top steel force Cs,net
65.59 kip
Tension steel force Ts
280.8 kip
Screening
Tension controlled · Moment utilization 86.9%
Bending strength · Within limit
Minimum tension steel · Within limit
Tension control · Within limit
Positive pure bending of a nonprestressed rectangular beam. The calculation excludes combined axial force, shear, anchorage and the minimum-steel exception in §9.6.1.3.