Concrete Vc
39.47 kip
Stirrup Vs
176.06 kip
φVn
147.99 kip
Spacing max
6.5 in
Anatomy Diagrammatic scale
Parameter-linked shear drawing. Diagrammatic scale.
STIRRUP ELEVATION d bw 12 in s 7 in Vs 176.06 kip
Screening Limit exceeded
Shear utilization 81.1%
Table 22.5.5.1(a) 18.9% below the threshold
Shear strength Vu ≤ φ(Vc + Vs, credited)
Within limit Diagonal compression Required Vs ≤ 8√f′c bw d
Within limit Minimum stirrup area Av ≥ Av,min when Vu > φλ√f′c bw d
Within limit Stirrup spacing Longitudinal spacing ≤ smax
Outside limit
Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.
Calculation readout Quantity Value
Concrete shear Vc 39.47 kip Provided stirrup Vs 176.06 kip Design shear φVn 147.99 kip Maximum stirrup spacing 6.5 in Minimum stirrup area Av,min 0.07 in² Minimum steel demand trigger 14.8 kip Required stirrup Vs 120.53 kip Diagonal compression Vs cap 157.86 kip Size effect λs (applied) 1 Longitudinal ratio ρw 0.76 % Axial stress contribution 0 psi Transverse yield used 60 ksi
Share link
Reset defaults
JSON
CSV
SVG
PNG ×2
Print A4
Starting inputs
Overall depth h 29 in
Effective depth d 26 in
Factored shear Vu 120 kip
Leg area Av 0.79 in²
Stirrup spacing s 7 in
Calculated result
Concrete shear Vc 39.47 kip
Provided stirrup Vs 176.06 kip
Design shear φVn 147.99 kip
Maximum stirrup spacing 6.5 in Once the tighter band applies, compare spacing with d/4 and 12 in. Adequate shear strength does not excuse excess spacing.
Preset screening · Table 22.5.5.1(a) · Limit exceeded
Use Table 22.5.5.1(a) when Av reaches Av,min. Below Av,min, use (c) with λs and ρw = As/(bw d). Cap the axial compression stress term at 0.05f′c and floor Vc at zero. Limit √f′c to 100 for the concrete term unless minimum web steel is present. Take Vs = Av fyt d/s, limiting fyt to 60 ksi for deformed-bar stirrups. Calculate φVn with φ = 0.75 and cap the credited Vs at 8√f′c bw d. Check the required Vs against that section limit. Use max(0.75√f′c, 50)bw s/fyt for Av,min and apply the ordinary-beam trigger Vu > φλ√f′c bw d. Select the spacing band from required Vs per Table 9.7.6.2.2: min(d/2, 24 in) up to 4√f′c bw d, then min(d/4, 12 in).
RebarStructLab • ACI 318-19 • US
§9.6 / §9.7 / §22.5
High shear changes the spacing band
Vertical stirrups · rectangular web · Limit exceeded
Inputs
Web width bw 12 in
Overall depth h 29 in
Effective depth d 26 in
Longitudinal steel As 2.37 in²
Axial Nu (+ compression) 0 kip
Factored shear Vu 120 kip
Concrete strength f′c 4,000 psi
Lightweight factor λ 1
Leg area Av 0.79 in²
Stirrup spacing s 7 in
Transverse yield fyt 60 ksi
Calculated values
Concrete shear Vc 39.47 kip
Provided stirrup Vs 176.06 kip
Design shear φVn 147.99 kip
Maximum stirrup spacing 6.5 in
Minimum stirrup area Av,min 0.07 in²
Minimum steel demand trigger 14.8 kip
Required stirrup Vs 120.53 kip
Diagonal compression Vs cap 157.86 kip
Size effect λs (applied) 1
Longitudinal ratio ρw 0.76 %
Axial stress contribution 0 psi
Transverse yield used 60 ksi
Parameter-linked shear drawing. Diagrammatic scale.
STIRRUP ELEVATION d bw 12 in s 7 in Vs 176.06 kip
Screening
Table 22.5.5.1(a) · Shear utilization 81.1%
Shear strength · Within limitDiagonal compression · Within limitMinimum stirrup area · Within limitStirrup spacing · Outside limit
Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.