ACI 318-19 §8.7 / §22.6

Interior slab-column punching section

A central rectangular reaction sends direct shear through a four-sided critical section.

Edit inputs ↓

Inputs

Editable example

Reaction & slab
Shear reinforcement
Perimeter bo 106in
Baseline φVc 150.84kip
φVn 150.84kip
Size λs 1 
AnatomyDiagrammatic scale
Parameter-linked punching drawing. Diagrammatic scale. INTERIOR COLUMN PLANCritical linec₁ 18 ind/2 3.75 inbo 106 in

Screening

Within screening limits
Punching utilization76.2%
(a) basic stress23.8% below the threshold
  • Concrete punching strengthVu ≤ φVc at the inner perimeter
    Within limit

Direct shear only. Supply net Vu at the section. Check unbalanced moment, openings, slab edge offsets, the actual perimeter geometry and local slab flexural steel per §8.6.1.2. For studs, provide the shortest enclosing outer perimeter and verify head, rail and cover detailing.

Calculation readout
QuantityValue
Inner critical perimeter bo106 in
Unreinforced strength φVc150.84 kip
Governing design shear φVn150.84 kip
Size effect factor λs1
Inner demand stress vu144.65 psi
Column aspect ratio βc1.11
Position factor αs40
Concrete stress eq. (a)252.98 psi
Concrete stress eq. (b)354.18 psi
Concrete stress eq. (c)305.49 psi

Original example

Worked solution

Default calculator ↗

Starting inputs

Column position
Interior
Column dimension c₁
18 in
Column dimension c₂
20 in
Average effective depth d
7.5 in

Calculated result

Inner critical perimeter bo
106 in
Unreinforced strength φVc
150.84 kip
Governing design shear φVn
150.84 kip
Size effect factor λs
1

Offset each supported face by d/2. Compute each stress equation and use the smallest before applying the strength factor.

Preset screening · (a) basic stress · Within limits

How the check works

Code basis ↗
  1. Measure bo at d/2 with the column faces flush at modeled free edges. Use the lesser of the three stress equations in Table 22.6.5.2, with βc = long side/short side, αs = 40/30/20 and √f′c limited to 100.
  2. For headed studs, use Table 22.6.6.1 for inner concrete stress and add Vs = Av fyt d/s. Use the actual √f′c for the Table 22.6.6.3 inner ceiling and Table 8.7.7.1.2 spacing threshold. Apply the 100 psi root cap to concrete stress, including 2λsλ√f′c at the supplied outer perimeter.
  3. Apply the full entered net shear to both sections as a conservative outer-perimeter screen. Check Av/s ≥ 2√f′c bo/fyt with actual √f′c per §22.6.8.3 and check the first-row, radial and tangential spacing limits.