ACI 318-19 §25.3 / §25.4 / §25.5

180° hook with insufficient return tail

A No. 11 bar turns back through 180°, with less straight return length than the standard detail requires.

Edit inputs ↓

Inputs

Editable example

Bar & bond
Available geometry
Straight ℓd 55.04in
Hook ℓdh 40.18in
Class B lap 71.55in
Confinement 2.5 
AnatomyDiagrammatic scale
Parameter-linked development drawing. Diagrammatic scale. 180° STANDARD HOOKCriticalsectionStraight ℓddb 1.41 inℓdh 40.18 inTail 5.64 in

Screening

Limit exceeded
Required / available length89.3%
180° standard hook10.7% below the threshold
  • Available embedmentAvailable length ≥ required length for the selected detail
    Within limit
  • Hook tail runTail ≥ max(4db, 2.5 in)
    Outside limit
  • Bend envelopeClear envelope ≥ minimum inside bend diameter + 2db
    Within limit

Ordinary nonseismic tension details. Available length is measured along the straight bar or to the outside of the hook. Check minimum cover, bend fabrication and confinement at discontinuous ends separately.

Calculation readout
QuantityValue
Straight development ℓd55.04 in
Hook development ℓdh40.18 in
Class B with 1.3 × floored ℓd71.55 in
Confinement (cᵦ + Ktr)/db2.5
Nominal bar diameter db1.41 in
Spacing/cover term cᵦ4.205 in
Selected required length40.18 in
Class B minimum per §25.5.271.55 in
Minimum inside bend diameter11.28 in
90° straight tail16.92 in
180° straight tail5.64 in
Top cast ψt1
Epoxy ψe (straight)1
Size ψs1
Grade ψg1.15
Hook confinement ψr1
Hook location ψo1.25
Hook concrete ψc0.933

Original example

Worked solution

Default calculator ↗

Starting inputs

Bar size
#11
Concrete strength f′c
5,000 psi
Steel grade fy
80 ksi
Minimum clear cover
3.5 in
Bar spacing c/c
10 in
Detail to screen
180° standard hook
Available length
45 in
Clear hook tail run
4 in
Clear bend envelope
15 in

Calculated result

Straight development ℓd
55.04 in
Hook development ℓdh
40.18 in
Class B minimum per §25.5.2
71.55 in
Confinement (cᵦ + Ktr)/db
2.5

The return tail has both a bar-diameter and a fixed minimum. Passing embedment alone does not make the bend a standard hook.

Preset screening · 180° standard hook · Limit exceeded

How the check works

Code basis ↗
  1. Use cᵦ = min(clear cover + db/2, bar spacing/2). Cap (cᵦ + Ktr)/db at 2.5, ψtψe at 1.7 and √f′c at 100. Calculate ℓd from Eq. (25.4.2.4a) with a 12 in floor.
  2. Check a Class B splice with the §25.5.2 minimum: multiply the unfloored ℓd by 1.3 and then apply the 12 in floor. The detail readout also shows 1.3 times the floored straight length for comparison.
  3. Use Eq. (25.4.3.1) and its own hook factors for ℓdh, subject to 8db and 6 in minima. A 90° hook needs a 12db tail; a 180° hook needs max(4db, 2.5 in). Check the outer bend envelope and tail run.