ACI 318-19 §25.3 / §25.4 / §25.5

Standard 90° hook in a column core

A bent tension bar enters a column core with space for the inside bend and tail.

Edit inputs ↓

Inputs

Editable example

Bar & bond
Available geometry
Straight ℓd 17.08in
Hook ℓdh 9.71in
Class B lap 22.2in
Confinement 2.5 
AnatomyDiagrammatic scale
Parameter-linked development drawing. Diagrammatic scale. 90° STANDARD HOOKCriticalsectionStraight ℓddb 0.75 inℓdh 9.71 inTail 9 in

Screening

Within screening limits
Required / available length60.7%
90° standard hook39.3% below the threshold
  • Available embedmentAvailable length ≥ required length for the selected detail
    Within limit
  • Hook tail runTail ≥ 12db
    Within limit
  • Bend envelopeClear envelope ≥ minimum inside bend diameter + 2db
    Within limit

Ordinary nonseismic tension details. Available length is measured along the straight bar or to the outside of the hook. Check minimum cover, bend fabrication and confinement at discontinuous ends separately.

Calculation readout
QuantityValue
Straight development ℓd17.08 in
Hook development ℓdh9.71 in
Class B with 1.3 × floored ℓd22.2 in
Confinement (cᵦ + Ktr)/db2.5
Nominal bar diameter db0.75 in
Spacing/cover term cᵦ3 in
Selected required length9.71 in
Class B minimum per §25.5.222.2 in
Minimum inside bend diameter4.5 in
90° straight tail9 in
180° straight tail3 in
Top cast ψt1
Epoxy ψe (straight)1
Size ψs0.8
Grade ψg1
Hook confinement ψr1
Hook location ψo1
Hook concrete ψc0.867

Original example

Worked solution

Default calculator ↗

Starting inputs

Minimum clear cover
3 in
Detail to screen
90° standard hook
Available length
16 in
Hook inside column core
Yes
Clear hook tail run
10 in
Clear bend envelope
7 in

Calculated result

Straight development ℓd
17.08 in
Hook development ℓdh
9.71 in
Class B minimum per §25.5.2
22.2 in
Confinement (cᵦ + Ktr)/db
2.5

Use the hook equation and its location factor, then compare 12db and the outer bend profile with the available geometry.

Preset screening · 90° standard hook · Within limits

How the check works

Code basis ↗
  1. Use cᵦ = min(clear cover + db/2, bar spacing/2). Cap (cᵦ + Ktr)/db at 2.5, ψtψe at 1.7 and √f′c at 100. Calculate ℓd from Eq. (25.4.2.4a) with a 12 in floor.
  2. Check a Class B splice with the §25.5.2 minimum: multiply the unfloored ℓd by 1.3 and then apply the 12 in floor. The detail readout also shows 1.3 times the floored straight length for comparison.
  3. Use Eq. (25.4.3.1) and its own hook factors for ℓdh, subject to 8db and 6 in minima. A 90° hook needs a 12db tail; a 180° hook needs max(4db, 2.5 in). Check the outer bend envelope and tail run.