16-inch standing-seam panels on a gable
A 48 ft building has one foot of rake overhang on both ends and two equal roof sides. Lay out 16-inch net-coverage panels.
Worked calculation
Each eave is 50 ft long. Divide by 16 inches of coverage and round up to 38 panels for each of the two sides.
Change the inputs to test your own measurements. Reset restores this example.
Results
LiveCorrect the highlighted inputs to update your results.
- Total panels
- Panel cut length
- Panels per side
- Eave length with overhangs
- Last panel net strip
- Roof panel coverage
- Ridge or high-side trim
- Ridge or high-side pieces
- Rake trim
- Rake pieces
- Eave drip trim
- Eave drip pieces
- Closure strip length
- Closure strips
- Clip or screw positions
Worksheet inputs US customary
- Roof shape
- Gable · two equal sides
- Panel length input
- Building span and pitch
- Building length parallel to eave
- 48 ft
- Full horizontal building span
- 28 ft
- Roof pitch
- 4:12
- Rake overhang at each end
- 1 ft
- Extra cut length along slope
- 2 in
- Panel system
- Standing seam (clip estimate)
- Panel net coverage width
- 16 in
- Trim stock length
- 10 ft
- Overlap at each trim joint
- 0.5 ft
- Closure strip coverage per piece
- 3 ft
- Fastening points per 100 ft² (9.29 m²)
- 80
Apply this example to your roof
Match panel minimum slope, field detailing, clips, edge fastening and thermal movement to the system drawings. Confirm manufacturable cut lengths, delivery limits and exact trim and closure profiles before ordering.
Frequently asked questions
Why does the 16-inch gable use 38 panels per side?
The required eave length is 600 inches. At 16 inches per panel, it takes 37 full widths plus a final strip.
Should clip spacing come from the gable example’s fastener estimate?
Use the assembly schedule for actual clip spacing. The calculator uses a rate per roof area for budgeting.