Metal trim stock with joint overlaps

A 24 ft shed roof high edge uses 10 ft flashing stock with a 1 ft overlap at each joint.

Worked calculation

Two stock pieces cover 19 ft after the lap. Three cover 28 ft, enough for the high side. Rake and eave pieces are counted as separate runs.

Change the inputs to test your own measurements. Reset restores this example.

Inputs

Units
Roof dimensions
ft
ft
:12
ft
in
Panel and trim stock
ft
ft
ft
Use the clip or screw rate specified for your panel assembly.

Results

Live

Panel seams and trim layoutTotal panels 12. Panel cut length 12.54 ft. RIBBED PANEL12 panels per sideCut 12.54 ftEave 24 ft
Panel seams and trim layout Schematic
Panels per side
12
Eave length with overhangs
24 ft
Last panel net strip
24 in
Roof panel coverage
300.86 ft²
Ridge or high-side trim
24 ft
Ridge or high-side pieces
3
Rake trim
25.07 ft
Rake pieces
4
Eave drip trim
24 ft
Eave drip pieces
3
Closure strip length
48 ft
Closure strips
16
Clip or screw positions
241

Apply this example to your roof

Match panel minimum slope, field detailing, clips, edge fastening and thermal movement to the system drawings. Confirm manufacturable cut lengths, delivery limits and exact trim and closure profiles before ordering.

Read the calculator method and references

Frequently asked questions

Why does a 24-foot high side need three trim pieces?

At a 1 ft joint lap the first piece covers 10 ft and each following piece adds 9 ft. Two reach only 19 ft.

Can metal trim offcuts reduce the number of stock lengths?

Possibly. Make a cut list before purchase and verify lap direction and minimum usable offcut length. The estimate counts runs separately.