Ground-to-roof estimate from 40 psf
A 2,000 ft² roof is checked with a 40 psf ground value, Ce of 1.0, Ct of 1.1 and a supplied Cs of 1.0.
Worked calculation
The simplified balanced expression gives 0.7 × 1.0 × 1.1 × 40 = 30.8 psf. Across the projected roof this is 61,600 lbf.
Change the inputs to test your own measurements. Reset restores this example.
Results
LiveCorrect the highlighted inputs to update your results.
- Balanced sloped roof estimate
- Observed local layer pressure
- Balanced flat roof estimate
- Slope factor Cs
- Roof angle
- Balanced roof weight
- Balanced weight equivalent
- Same snow depth at powder density
- Same snow depth at wet-snow density
- Observed snow layer pressure
- Ice pressure over affected area
- Area-average observed pressure
- Observed roof weight
- Observed weight equivalent
- Entered comparison threshold
- Powder density assumption
- Wet snow density assumption
- Ice density assumption
- Selected snow density
Worksheet inputs US customary
- Horizontal roof area
- 2,000 ft²
- Ground snow load Pg
- 40 psf
- Exposure factor Ce
- 1×
- Thermal factor Ct
- 1.1×
- Roof pitch
- 6:12
- Slope factor source
- Use a supplied Cs
- Supplied slope factor Cs
- 1×
- Comparison threshold
- 35 psf
- Snow density
- Wet snow · dense
- Vertical snow depth
- 12 in
- Vertical ice thickness
- 1 in
- Projected roof area covered by ice
- 15%
Apply this example to your roof
A structural design needs the applicable code, hazard data, factors, minimums and load combinations. This balanced expression omits drift, sliding, rain-on-snow and localized effects. The entered threshold is a comparison input and cannot establish structural adequacy.
Frequently asked questions
Why multiply the 30.8 psf roof estimate by plan area?
The balanced pressure is applied to the horizontal projection. That reference area is also used for the total load.
Is the 35 psf threshold a stock capacity for this roof?
It is an example comparison input. Use a documented project threshold on the same loading basis.