Ground-to-roof estimate from 40 psf

A 2,000 ft² roof is checked with a 40 psf ground value, Ce of 1.0, Ct of 1.1 and a supplied Cs of 1.0.

Worked calculation

The simplified balanced expression gives 0.7 × 1.0 × 1.1 × 40 = 30.8 psf. Across the projected roof this is 61,600 lbf.

Change the inputs to test your own measurements. Reset restores this example.

Inputs

Units
Balanced load inputs
ft²
psf
×
×
:12
×
psf Enter a documented limit on the same load basis.
Observed snow and ice layers
in
in
%

Results

Live

Roof snow and ice layersBalanced sloped roof estimate 30.8 psf. Observed local layer pressure 24.77 psf. Balanced loadObserved locally30.8 psf24.77 psfArea 2,000 ft²Ice area 15%
Roof snow and ice layers Schematic
Balanced flat roof estimate
30.8 psf
Slope factor Cs
1
Roof angle
26.57°
Balanced roof weight
61,600 lbf
Balanced weight equivalent
30.8 US tons equiv.
Same snow depth at powder density
5 psf
Same snow depth at wet-snow density
20 psf
Observed snow layer pressure
20 psf
Ice pressure over affected area
4.77 psf
Area-average observed pressure
20.72 psf
Observed roof weight
41,430 lbf
Observed weight equivalent
20.72 US tons equiv.
Entered comparison threshold
35 psf
Powder density assumption
5 lb/ft³
Wet snow density assumption
20 lb/ft³
Ice density assumption
57.2 lb/ft³
Selected snow density
20 lb/ft³

Apply this example to your roof

A structural design needs the applicable code, hazard data, factors, minimums and load combinations. This balanced expression omits drift, sliding, rain-on-snow and localized effects. The entered threshold is a comparison input and cannot establish structural adequacy.

Read the calculator method and references

Frequently asked questions

Why multiply the 30.8 psf roof estimate by plan area?

The balanced pressure is applied to the horizontal projection. That reference area is also used for the total load.

Is the 35 psf threshold a stock capacity for this roof?

It is an example comparison input. Use a documented project threshold on the same loading basis.