Roof threshold check with custom snow density

A roof has 24 inches of observed dense snow, estimated at 28 lb/ft³. Compare it with a documented 45 psf threshold.

Worked calculation

The 2 ft layer applies 56 psf in the uniform observation model. The entered threshold screening alert uses that pressure separately from the balanced ground-load calculation.

Change the inputs to test your own measurements. Reset restores this example.

Inputs

Units
Balanced load inputs
ft²
psf
×
×
:12
×
psf Enter a documented limit on the same load basis.
Observed snow and ice layers
lb/ft³
in
in
%

Results

Live

Roof snow and ice layersBalanced sloped roof estimate 34.65 psf. Observed local layer pressure 56 psf. Balanced loadObserved locally34.65 psf56 psfArea 1,400 ft²Ice area 0%
Roof snow and ice layers Schematic
Balanced flat roof estimate
34.65 psf
Slope factor Cs
1
Roof angle
26.57°
Balanced roof weight
48,510 lbf
Balanced weight equivalent
24.26 US tons equiv.
Same snow depth at powder density
10 psf
Same snow depth at wet-snow density
40 psf
Observed snow layer pressure
56 psf
Ice pressure over affected area
0 psf
Area-average observed pressure
56 psf
Observed roof weight
78,400 lbf
Observed weight equivalent
39.2 US tons equiv.
Entered comparison threshold
45 psf
Powder density assumption
5 lb/ft³
Wet snow density assumption
20 lb/ft³
Ice density assumption
57.2 lb/ft³
Selected snow density
28 lb/ft³
  • The observed layer estimate exceeds the entered comparison threshold.

Apply this example to your roof

A structural design needs the applicable code, hazard data, factors, minimums and load combinations. This balanced expression omits drift, sliding, rain-on-snow and localized effects. The entered threshold is a comparison input and cannot establish structural adequacy.

Read the calculator method and references

Frequently asked questions

How much roof-wide force does the 56 psf measured layer imply?

At 1,400 ft² of projected area it is 78,400 lbf for the uniform layer assumption.

Should I add the 56 psf to the ground-to-roof result?

They describe separate estimates. Compare each on its own basis and use the applicable load combinations for design.