Roof threshold check with custom snow density
A roof has 24 inches of observed dense snow, estimated at 28 lb/ft³. Compare it with a documented 45 psf threshold.
Worked calculation
The 2 ft layer applies 56 psf in the uniform observation model. The entered threshold screening alert uses that pressure separately from the balanced ground-load calculation.
Change the inputs to test your own measurements. Reset restores this example.
Results
LiveCorrect the highlighted inputs to update your results.
- Balanced sloped roof estimate
- Observed local layer pressure
- Balanced flat roof estimate
- Slope factor Cs
- Roof angle
- Balanced roof weight
- Balanced weight equivalent
- Same snow depth at powder density
- Same snow depth at wet-snow density
- Observed snow layer pressure
- Ice pressure over affected area
- Area-average observed pressure
- Observed roof weight
- Observed weight equivalent
- Entered comparison threshold
- Powder density assumption
- Wet snow density assumption
- Ice density assumption
- Selected snow density
- The observed layer estimate exceeds the entered comparison threshold.
Worksheet inputs US customary
- Horizontal roof area
- 1,400 ft²
- Ground snow load Pg
- 45 psf
- Exposure factor Ce
- 1×
- Thermal factor Ct
- 1.1×
- Roof pitch
- 6:12
- Slope factor source
- Use a supplied Cs
- Supplied slope factor Cs
- 1×
- Comparison threshold
- 45 psf
- Snow density
- Enter a density
- Measured or assumed snow density
- 28 lb/ft³
- Vertical snow depth
- 24 in
- Vertical ice thickness
- 0 in
- Projected roof area covered by ice
- 0%
Apply this example to your roof
A structural design needs the applicable code, hazard data, factors, minimums and load combinations. This balanced expression omits drift, sliding, rain-on-snow and localized effects. The entered threshold is a comparison input and cannot establish structural adequacy.
Frequently asked questions
How much roof-wide force does the 56 psf measured layer imply?
At 1,400 ft² of projected area it is 78,400 lbf for the uniform layer assumption.
Should I add the 56 psf to the ground-to-roof result?
They describe separate estimates. Compare each on its own basis and use the applicable load combinations for design.