Roof weight with an ice band at the eave
A 1,000 ft² roof has a foot of wet snow and a 2-inch ice band over 10% of its projected area.
Worked calculation
The storm layer contributes 20 psf everywhere. In the band the ice adds about 9.53 psf. Spread across the roof, that band adds about 0.95 psf to the observed area average.
Change the inputs to test your own measurements. Reset restores this example.
Results
LiveCorrect the highlighted inputs to update your results.
- Balanced sloped roof estimate
- Observed local layer pressure
- Balanced flat roof estimate
- Slope factor Cs
- Roof angle
- Balanced roof weight
- Balanced weight equivalent
- Same snow depth at powder density
- Same snow depth at wet-snow density
- Observed snow layer pressure
- Ice pressure over affected area
- Area-average observed pressure
- Observed roof weight
- Observed weight equivalent
- Entered comparison threshold
- Powder density assumption
- Wet snow density assumption
- Ice density assumption
- Selected snow density
- The observed layer estimate exceeds the entered comparison threshold.
Worksheet inputs US customary
- Horizontal roof area
- 1,000 ft²
- Ground snow load Pg
- 28 psf
- Exposure factor Ce
- 1×
- Thermal factor Ct
- 1.1×
- Roof pitch
- 6:12
- Slope factor source
- Use a supplied Cs
- Supplied slope factor Cs
- 1×
- Comparison threshold
- 25 psf
- Snow density
- Wet snow · dense
- Vertical snow depth
- 12 in
- Vertical ice thickness
- 2 in
- Projected roof area covered by ice
- 10%
Apply this example to your roof
A structural design needs the applicable code, hazard data, factors, minimums and load combinations. This balanced expression omits drift, sliding, rain-on-snow and localized effects. The entered threshold is a comparison input and cannot establish structural adequacy.
Frequently asked questions
How does 10% ice coverage affect the eave band pressure?
The local layer still includes the full 9.53 psf ice pressure. The 10% value scales the ice contribution to roof-wide weight.
Why check the eave band even though the average is under 25 psf?
The estimate at the band exceeds 25 psf. A concentrated eave condition needs its own structural and drainage review.