Roof weight with an ice band at the eave

A 1,000 ft² roof has a foot of wet snow and a 2-inch ice band over 10% of its projected area.

Worked calculation

The storm layer contributes 20 psf everywhere. In the band the ice adds about 9.53 psf. Spread across the roof, that band adds about 0.95 psf to the observed area average.

Change the inputs to test your own measurements. Reset restores this example.

Inputs

Units
Balanced load inputs
ft²
psf
×
×
:12
×
psf Enter a documented limit on the same load basis.
Observed snow and ice layers
in
in
%

Results

Live

Roof snow and ice layersBalanced sloped roof estimate 21.56 psf. Observed local layer pressure 29.53 psf. Balanced loadObserved locally21.56 psf29.53 psfArea 1,000 ft²Ice area 10%
Roof snow and ice layers Schematic
Balanced flat roof estimate
21.56 psf
Slope factor Cs
1
Roof angle
26.57°
Balanced roof weight
21,560 lbf
Balanced weight equivalent
10.78 US tons equiv.
Same snow depth at powder density
5 psf
Same snow depth at wet-snow density
20 psf
Observed snow layer pressure
20 psf
Ice pressure over affected area
9.53 psf
Area-average observed pressure
20.95 psf
Observed roof weight
20,953.33 lbf
Observed weight equivalent
10.48 US tons equiv.
Entered comparison threshold
25 psf
Powder density assumption
5 lb/ft³
Wet snow density assumption
20 lb/ft³
Ice density assumption
57.2 lb/ft³
Selected snow density
20 lb/ft³
  • The observed layer estimate exceeds the entered comparison threshold.

Apply this example to your roof

A structural design needs the applicable code, hazard data, factors, minimums and load combinations. This balanced expression omits drift, sliding, rain-on-snow and localized effects. The entered threshold is a comparison input and cannot establish structural adequacy.

Read the calculator method and references

Frequently asked questions

How does 10% ice coverage affect the eave band pressure?

The local layer still includes the full 9.53 psf ice pressure. The 10% value scales the ice contribution to roof-wide weight.

Why check the eave band even though the average is under 25 psf?

The estimate at the band exceeds 25 psf. A concentrated eave condition needs its own structural and drainage review.