Slope-factor sensitivity on a 12:12 roof

A 45° roof is used to explore how an illustrative slope factor changes the balanced pressure for a 60 psf ground value.

Worked calculation

The example curve gives Cs = (70 − 45) / 40 = 0.625. Apply it to the 42 psf flat estimate for a 26.25 psf sensitivity result.

Change the inputs to test your own measurements. Reset restores this example.

Inputs

Units
Balanced load inputs
ft²
psf
×
×
:12
psf Enter a documented limit on the same load basis.
Observed snow and ice layers
in
in
%

Results

Live

Roof snow and ice layersBalanced sloped roof estimate 26.25 psf. Observed local layer pressure 24.77 psf. Balanced loadObserved locally26.25 psf24.77 psfArea 1,400 ft²Ice area 15%
Roof snow and ice layers Schematic
Balanced flat roof estimate
42 psf
Slope factor Cs
0.625
Roof angle
45°
Balanced roof weight
36,750 lbf
Balanced weight equivalent
18.38 US tons equiv.
Same snow depth at powder density
5 psf
Same snow depth at wet-snow density
20 psf
Observed snow layer pressure
20 psf
Ice pressure over affected area
4.77 psf
Area-average observed pressure
20.72 psf
Observed roof weight
29,001 lbf
Observed weight equivalent
14.5 US tons equiv.
Entered comparison threshold
32 psf
Powder density assumption
5 lb/ft³
Wet snow density assumption
20 lb/ft³
Ice density assumption
57.2 lb/ft³
Selected snow density
20 lb/ft³
  • The illustrative slope curve is a sensitivity aid. Use a project-specific Cs for a code calculation.

Apply this example to your roof

A structural design needs the applicable code, hazard data, factors, minimums and load combinations. This balanced expression omits drift, sliding, rain-on-snow and localized effects. The entered threshold is a comparison input and cannot establish structural adequacy.

Read the calculator method and references

Frequently asked questions

Where does the 0.625 steep-roof slope factor come from?

It comes from the tool’s labeled illustrative curve. Use a project-specific Cs for an adopted-code design.

What happens if I enter a supplied Cs of 1.0 for the 45° roof?

The balanced estimate equals the 42 psf flat value. The actual choice depends on the assembly and the applicable standard.