Roof Snow Load, Ice Dam Weight & Ground Conversion Calculator
Compare a balanced ground-to-roof estimate with the pressure and weight of observed snow and ice layers.
Results
LiveCorrect the highlighted inputs to update your results.
- Balanced sloped roof estimate
- Observed local layer pressure
- Balanced flat roof estimate
- Slope factor Cs
- Roof angle
- Balanced roof weight
- Balanced weight equivalent
- Same snow depth at powder density
- Same snow depth at wet-snow density
- Observed snow layer pressure
- Ice pressure over affected area
- Area-average observed pressure
- Observed roof weight
- Observed weight equivalent
- Entered comparison threshold
- Powder density assumption
- Wet snow density assumption
- Ice density assumption
- Selected snow density
Worksheet inputs US customary
- Horizontal roof area
- 2,000 ft²
- Ground snow load Pg
- 40 psf
- Exposure factor Ce
- 1×
- Thermal factor Ct
- 1.1×
- Roof pitch
- 6:12
- Slope factor source
- Use a supplied Cs
- Supplied slope factor Cs
- 1×
- Comparison threshold
- 35 psf
- Snow density
- Wet snow · dense
- Vertical snow depth
- 12 in
- Vertical ice thickness
- 1 in
- Projected roof area covered by ice
- 15%
Compare balanced load and observed layers
- The balanced flat screening expression is 0.7 × Ce × Ct × Pg. Apply the supplied Cs for the sloped result. The optional angle curve stays at one through 30° and falls linearly to zero at 70° for sensitivity only.
- For an observed layer, multiply its vertical depth in feet by its density in pounds per cubic foot. The worksheet illustrates powder at 5, wet snow at 20 and ice at 57.2 lb/ft³.
- Apply ice pressure to the fraction of roof it covers for total weight. The local pressure in the ice zone includes the full ice layer. Compare both screening pressures with a documented threshold on the same basis.
A structural design needs the applicable code, hazard data, factors, minimums and load combinations. This balanced expression omits drift, sliding, rain-on-snow and localized effects. The entered threshold is a comparison input and cannot establish structural adequacy.
References
Frequently asked questions
What is the difference between ground snow load and roof snow load?
Ground snow load describes a site hazard value. A roof estimate adjusts it for how the roof accumulates and retains snow.
How does a measured ice band affect total roof weight?
Multiply local band pressure by the projected area of the band. That contribution adds to the weight of the snow layer over the full projection.
Can the snow threshold result determine if my roof is safe?
A threshold comparison is a screening result. Structural adequacy depends on the actual framing, load combinations, localized effects and condition of the building.