Roof Snow Load, Ice Dam Weight & Ground Conversion Calculator

Compare a balanced ground-to-roof estimate with the pressure and weight of observed snow and ice layers.

Inputs

Units
Balanced load inputs
ft²
psf
×
×
:12
×
psf Enter a documented limit on the same load basis.
Observed snow and ice layers
in
in
%

Results

Live

Roof snow and ice layersBalanced sloped roof estimate 30.8 psf. Observed local layer pressure 24.77 psf. Balanced loadObserved locally30.8 psf24.77 psfArea 2,000 ft²Ice area 15%
Roof snow and ice layers Schematic
Balanced flat roof estimate
30.8 psf
Slope factor Cs
1
Roof angle
26.57°
Balanced roof weight
61,600 lbf
Balanced weight equivalent
30.8 US tons equiv.
Same snow depth at powder density
5 psf
Same snow depth at wet-snow density
20 psf
Observed snow layer pressure
20 psf
Ice pressure over affected area
4.77 psf
Area-average observed pressure
20.72 psf
Observed roof weight
41,430 lbf
Observed weight equivalent
20.72 US tons equiv.
Entered comparison threshold
35 psf
Powder density assumption
5 lb/ft³
Wet snow density assumption
20 lb/ft³
Ice density assumption
57.2 lb/ft³
Selected snow density
20 lb/ft³

Compare balanced load and observed layers

  1. The balanced flat screening expression is 0.7 × Ce × Ct × Pg. Apply the supplied Cs for the sloped result. The optional angle curve stays at one through 30° and falls linearly to zero at 70° for sensitivity only.
  2. For an observed layer, multiply its vertical depth in feet by its density in pounds per cubic foot. The worksheet illustrates powder at 5, wet snow at 20 and ice at 57.2 lb/ft³.
  3. Apply ice pressure to the fraction of roof it covers for total weight. The local pressure in the ice zone includes the full ice layer. Compare both screening pressures with a documented threshold on the same basis.

A structural design needs the applicable code, hazard data, factors, minimums and load combinations. This balanced expression omits drift, sliding, rain-on-snow and localized effects. The entered threshold is a comparison input and cannot establish structural adequacy.

References

Frequently asked questions

What is the difference between ground snow load and roof snow load?

Ground snow load describes a site hazard value. A roof estimate adjusts it for how the roof accumulates and retains snow.

How does a measured ice band affect total roof weight?

Multiply local band pressure by the projected area of the band. That contribution adds to the weight of the snow layer over the full projection.

Can the snow threshold result determine if my roof is safe?

A threshold comparison is a screening result. Structural adequacy depends on the actual framing, load combinations, localized effects and condition of the building.