Indoor sound field & critical distance

Split direct and reverberant sound at a receiver and estimate the benefit of acoustic ceiling treatment.

Inputs

Room & source
Absorption change
Sound level
86dB
Critical dist.
1.17m
Direct share
7.9%
Level drop
3.45dB

Direct and reflected energy paths

Illustrative scale
Room sound paths and critical distanceTwo reflected rays and a direct ray reach the receiver. A dashed marker shows the critical distance inside the drawable range.SOURCERECEIVERr 4 mDᶜ 1.17 m
Direct fieldReflectionsReceiver

Receiver target exceeded

Limit

The modelled value falls on the wrong side of the entered target.

≥ 3 dB reserveReviewOver target

Calculation breakdown

Room constant R
34.29 m²
Direct level
74.98 dB
Reverberant level
85.67 dB
Receiver regime
Reverberant dominated
Treated mean absorption α
0.32
Treated receiver level
82.57 dB
Diffuse-only level drop
3.93 dB