RoomAcousticLab · Calculation record
Indoor sound field example
Absorptive workshop ceiling
A machine is measured at a receiver across a workshop. Estimate how much a ceiling finish change lowers the total level and the diffuse portion.
Inputs
- Sound level
- 90.6dB
- Critical dist.
- 1.36m
- Direct share
- 4.9%
- Level drop
- 4.31dB
Direct and reflected energy paths
Illustrative scaleReceiver target exceeded
LimitThe modelled value falls on the wrong side of the entered target.
≥ 3 dB reserveReviewOver target
Input snapshot
- Total surface area
- 340 m²
- Mean absorption α
- 0.12
- Sound power Lw
- 101 dB
- Directivity Q
- 2 · Half space
- Receiver distance
- 6 m
- Receiver target
- 88 dB
- Treatment option
- Replace ceiling finish
- Ceiling area treated
- 80 m²
- Existing ceiling α
- 0.07
- New ceiling α
- 0.78
Calculation breakdown
- Room constant R
- 46.36 m²
- Direct level
- 77.46 dB
- Reverberant level
- 90.36 dB
- Receiver regime
- Reverberant dominated
- Treated mean absorption α
- 0.2871
- Treated receiver level
- 86.27 dB
- Diffuse-only level drop
- 4.7 dB
At ᾱ = 1, R diverges and the diffuse term vanishes. At ᾱ = 0, the ideal enclosure has no finite steady-state reverberant level. The model omits discrete room modes and early-reflection interference.