RoomAcousticLab · Calculation record
Indoor sound field example
Distant warehouse receiver
A receiver far across a hard-sided warehouse sits well beyond critical distance. Compare the untreated and doubled-absorption estimates.
Inputs
- Sound level
- 93.1dB
- Critical dist.
- 1.58m
- Direct share
- 1%
- Level drop
- 3.25dB
Direct and reflected energy paths
Illustrative scaleReceiver target exceeded
LimitThe modelled value falls on the wrong side of the entered target.
≥ 3 dB reserveReviewOver target
Input snapshot
- Total surface area
- 980 m²
- Mean absorption α
- 0.06
- Sound power Lw
- 105 dB
- Directivity Q
- 2 · Half space
- Receiver distance
- 16 m
- Receiver target
- 92 dB
- Treatment option
- Double mean absorption
Calculation breakdown
- Room constant R
- 62.55 m²
- Direct level
- 72.94 dB
- Reverberant level
- 93.06 dB
- Receiver regime
- Reverberant dominated
- Treated mean absorption α
- 0.12
- Treated receiver level
- 89.85 dB
- Diffuse-only level drop
- 3.3 dB
At ᾱ = 1, R diverges and the diffuse term vanishes. At ᾱ = 0, the ideal enclosure has no finite steady-state reverberant level. The model omits discrete room modes and early-reflection interference.