Indoor sound field example

Distant warehouse receiver

A receiver far across a hard-sided warehouse sits well beyond critical distance. Compare the untreated and doubled-absorption estimates.

Inputs

Room & source
Absorption change
Sound level
93.1dB
Critical dist.
1.58m
Direct share
1%
Level drop
3.25dB

Direct and reflected energy paths

Illustrative scale
Room sound paths and critical distanceTwo reflected rays and a direct ray reach the receiver. A dashed marker shows the critical distance inside the drawable range.SOURCERECEIVERr 16 mDᶜ 1.58 m
Direct fieldReflectionsReceiver

Receiver target exceeded

Limit

The modelled value falls on the wrong side of the entered target.

≥ 3 dB reserveReviewOver target

Calculation breakdown

Room constant R
62.55 m²
Direct level
72.94 dB
Reverberant level
93.06 dB
Receiver regime
Reverberant dominated
Treated mean absorption α
0.12
Treated receiver level
89.85 dB
Diffuse-only level drop
3.3 dB