RoomAcousticLab · Calculation record
Indoor sound field example
Test cell with a harder ceiling
Replacing an existing absorptive finish with a harder one is a deliberate adverse case. Check how the sign of the predicted level change reverses.
Inputs
- Sound level
- 84.5dB
- Critical dist.
- 1.3m
- Direct share
- 15.9%
- Level drop
- -3.04dB
Direct and reflected energy paths
Illustrative scaleSmall receiver reserve
ReviewThere is less than 3 dB of modelled reserve against the entered target.
≥ 3 dB reserveReviewOver target
Input snapshot
- Total surface area
- 110 m²
- Mean absorption α
- 0.28
- Sound power Lw
- 94 dB
- Directivity Q
- 2 · Half space
- Receiver distance
- 3 m
- Receiver target
- 86 dB
- Treatment option
- Replace ceiling finish
- Ceiling area treated
- 22 m²
- Existing ceiling α
- 0.85
- New ceiling α
- 0.2
Calculation breakdown
- Room constant R
- 42.78 m²
- Direct level
- 76.48 dB
- Reverberant level
- 83.71 dB
- Receiver regime
- Reverberant dominated
- Treated mean absorption α
- 0.15
- Treated receiver level
- 87.5 dB
- Diffuse-only level drop
- -3.43 dB
At ᾱ = 1, R diverges and the diffuse term vanishes. At ᾱ = 0, the ideal enclosure has no finite steady-state reverberant level. The model omits discrete room modes and early-reflection interference.