Room modes example

Cubical test room

Equal room dimensions pile several modes onto the same frequencies. Inspect the coincidences that the average Schroeder estimate cannot describe.

Inputs

Room geometry
Decay & air
First mode
49Hz
Schroeder
216Hz
Largest gap
20.3Hz
Coincidences
16

Standing waves & modal spectrum

Illustrative scale
Room plan and modal spectrumThe room plan illustrates standing-wave contours. Spectral lines show the first 18 modes with different heights and colours for their three families.ROOM PLANLOWEST 18 MODESL 3.5 mW 3.5 m49 Hz120.1 HzSchroeder 216 Hz
AxialTangentialOblique

Several modal screening flags

Limit

Review the ratio, coincidences, gaps and band counts before settling the dimensions.

Clear screenReviewMultiple flags

Calculation breakdown

Room volume
42.88 m³
Sound speed
343.2 m/s
H : W : L proportions
1 : 1 : 1
Approximate Bolt area
Outside
Bonello density screen
Review
Gap review threshold
20 Hz
Lowest 24 eigenmodes
ModeFamilyFrequency
(0, 0, 1)axial49.03 Hz
(0, 1, 0)axial49.03 Hz
(1, 0, 0)axial49.03 Hz
(0, 1, 1)tangential69.34 Hz
(1, 0, 1)tangential69.34 Hz
(1, 1, 0)tangential69.34 Hz
(1, 1, 1)oblique84.92 Hz
(0, 0, 2)axial98.06 Hz
(0, 2, 0)axial98.06 Hz
(2, 0, 0)axial98.06 Hz
(0, 1, 2)tangential109.64 Hz
(0, 2, 1)tangential109.64 Hz
(1, 0, 2)tangential109.64 Hz
(1, 2, 0)tangential109.64 Hz
(2, 0, 1)tangential109.64 Hz
(2, 1, 0)tangential109.64 Hz
(1, 1, 2)oblique120.1 Hz
(1, 2, 1)oblique120.1 Hz
(2, 1, 1)oblique120.1 Hz
(0, 2, 2)tangential138.68 Hz
(2, 0, 2)tangential138.68 Hz
(2, 2, 0)tangential138.68 Hz
(0, 0, 3)axial147.09 Hz
(0, 3, 0)axial147.09 Hz
Bonello band counts below Schroeder
Band centreModesCoincidence
20 Hz0—
25 Hz0—
31.5 Hz0—
40 Hz0—
50 Hz3Yes
63 Hz3Yes
80 Hz1—
100 Hz9Yes
125 Hz6Yes
160 Hz22Yes