Room modes example

Compact control room

List the first axial, tangential and oblique modes in a modest monitoring room. See where the stiff-boundary model crosses into the diffuse-field estimate.

Inputs

Room geometry
Decay & air
First mode
30.6Hz
Schroeder
135.5Hz
Largest gap
10.7Hz
Coincidences
0

Standing waves & modal spectrum

Illustrative scale
Room plan and modal spectrumThe room plan illustrates standing-wave contours. Spectral lines show the first 18 modes with different heights and colours for their three families.ROOM PLANLOWEST 18 MODESL 5.6 mW 4.15 m30.6 Hz105.1 HzSchroeder 135.5 Hz
AxialTangentialOblique

Clear on the listed screens

Pass

The proportions, spacing and sampled band counts fall within the listed screening criteria.

Clear screenReviewMultiple flags

Calculation breakdown

Room volume
69.72 m³
Sound speed
343.2 m/s
H : W : L proportions
1 : 1.383 : 1.867
Approximate Bolt area
Inside
Bonello density screen
Clear
Gap review threshold
20 Hz
Lowest 24 eigenmodes
ModeFamilyFrequency
(1, 0, 0)axial30.64 Hz
(0, 1, 0)axial41.35 Hz
(1, 1, 0)tangential51.47 Hz
(0, 0, 1)axial57.2 Hz
(2, 0, 0)axial61.29 Hz
(1, 0, 1)tangential64.89 Hz
(0, 1, 1)tangential70.58 Hz
(2, 1, 0)tangential73.93 Hz
(1, 1, 1)oblique76.95 Hz
(0, 2, 0)axial82.7 Hz
(2, 0, 1)tangential83.84 Hz
(1, 2, 0)tangential88.2 Hz
(3, 0, 0)axial91.93 Hz
(2, 1, 1)oblique93.48 Hz
(0, 2, 1)tangential100.56 Hz
(3, 1, 0)tangential100.8 Hz
(2, 2, 0)tangential102.94 Hz
(1, 2, 1)oblique105.12 Hz
(3, 0, 1)tangential108.28 Hz
(0, 0, 2)axial114.4 Hz
(3, 1, 1)oblique115.9 Hz
(2, 2, 1)oblique117.76 Hz
(1, 0, 2)tangential118.44 Hz
(0, 1, 2)tangential121.65 Hz
Bonello band counts below Schroeder
Band centreModesCoincidence
20 Hz0—
25 Hz0—
31.5 Hz1—
40 Hz1—
50 Hz1—
63 Hz4—
80 Hz5—
100 Hz7—