RoomAcousticLab · Calculation record
Room modes example
Lecture room crossover
A larger room with a 0.7-second decay moves the estimated crossover into the lower bands. Compare the available bands with the ranked eigenfrequencies.
Inputs
- First mode
- 12.3Hz
- Schroeder
- 66.7Hz
- Largest gap
- 6.8Hz
- Coincidences
- 0
Standing waves & modal spectrum
Illustrative scaleReview the modal distribution
ReviewAt least one check needs review or too few full bands are below Schroeder.
Clear screenReviewMultiple flags
Input snapshot
- Length
- 14 m
- Width
- 9 m
- Height
- 5 m
- Measured or predicted RT60
- 0.7 s
- Air temperature
- 23 °C
Calculation breakdown
- Room volume
- 630 m³
- Sound speed
- 345 m/s
- H : W : L proportions
- 1 : 1.8 : 2.8
- Approximate Bolt area
- Outside
- Bonello density screen
- Clear
- Gap review threshold
- 20 Hz
| Mode | Family | Frequency |
|---|---|---|
| (1, 0, 0) | axial | 12.32 Hz |
| (0, 1, 0) | axial | 19.16 Hz |
| (1, 1, 0) | tangential | 22.78 Hz |
| (2, 0, 0) | axial | 24.64 Hz |
| (2, 1, 0) | tangential | 31.22 Hz |
| (0, 0, 1) | axial | 34.5 Hz |
| (1, 0, 1) | tangential | 36.63 Hz |
| (3, 0, 0) | axial | 36.96 Hz |
| (0, 2, 0) | axial | 38.33 Hz |
| (0, 1, 1) | tangential | 39.46 Hz |
| (1, 2, 0) | tangential | 40.26 Hz |
| (1, 1, 1) | oblique | 41.34 Hz |
| (3, 1, 0) | tangential | 41.63 Hz |
| (2, 0, 1) | tangential | 42.39 Hz |
| (2, 2, 0) | tangential | 45.57 Hz |
| (2, 1, 1) | oblique | 46.52 Hz |
| (4, 0, 0) | axial | 49.28 Hz |
| (3, 0, 1) | tangential | 50.56 Hz |
| (0, 2, 1) | tangential | 51.57 Hz |
| (4, 1, 0) | tangential | 52.88 Hz |
| (1, 2, 1) | oblique | 53.02 Hz |
| (3, 2, 0) | tangential | 53.25 Hz |
| (3, 1, 1) | oblique | 54.07 Hz |
| (2, 2, 1) | oblique | 57.15 Hz |
| Band centre | Modes | Coincidence |
|---|---|---|
| 20 Hz | 1 | — |
| 25 Hz | 2 | — |
| 31.5 Hz | 2 | — |
| 40 Hz | 8 | — |
| 50 Hz | 9 | — |
Rigid rectangular boundaries give ideal eigenfrequencies. Construction details, source and listener placement, surface impedance and damping affect measured levels. The Schroeder frequency is an approximate crossover.