Room modes example

Lecture room crossover

A larger room with a 0.7-second decay moves the estimated crossover into the lower bands. Compare the available bands with the ranked eigenfrequencies.

Inputs

Room geometry
Decay & air
First mode
12.3Hz
Schroeder
66.7Hz
Largest gap
6.8Hz
Coincidences
0

Standing waves & modal spectrum

Illustrative scale
Room plan and modal spectrumThe room plan illustrates standing-wave contours. Spectral lines show the first 18 modes with different heights and colours for their three families.ROOM PLANLOWEST 18 MODESL 14 mW 9 m12.3 Hz50.6 HzSchroeder 66.7 Hz
AxialTangentialOblique

Review the modal distribution

Review

At least one check needs review or too few full bands are below Schroeder.

Clear screenReviewMultiple flags

Calculation breakdown

Room volume
630 m³
Sound speed
345 m/s
H : W : L proportions
1 : 1.8 : 2.8
Approximate Bolt area
Outside
Bonello density screen
Clear
Gap review threshold
20 Hz
Lowest 24 eigenmodes
ModeFamilyFrequency
(1, 0, 0)axial12.32 Hz
(0, 1, 0)axial19.16 Hz
(1, 1, 0)tangential22.78 Hz
(2, 0, 0)axial24.64 Hz
(2, 1, 0)tangential31.22 Hz
(0, 0, 1)axial34.5 Hz
(1, 0, 1)tangential36.63 Hz
(3, 0, 0)axial36.96 Hz
(0, 2, 0)axial38.33 Hz
(0, 1, 1)tangential39.46 Hz
(1, 2, 0)tangential40.26 Hz
(1, 1, 1)oblique41.34 Hz
(3, 1, 0)tangential41.63 Hz
(2, 0, 1)tangential42.39 Hz
(2, 2, 0)tangential45.57 Hz
(2, 1, 1)oblique46.52 Hz
(4, 0, 0)axial49.28 Hz
(3, 0, 1)tangential50.56 Hz
(0, 2, 1)tangential51.57 Hz
(4, 1, 0)tangential52.88 Hz
(1, 2, 1)oblique53.02 Hz
(3, 2, 0)tangential53.25 Hz
(3, 1, 1)oblique54.07 Hz
(2, 2, 1)oblique57.15 Hz
Bonello band counts below Schroeder
Band centreModesCoincidence
20 Hz1—
25 Hz2—
31.5 Hz2—
40 Hz8—
50 Hz9—