A narrow gallery has many low longitudinal harmonics before transverse modes appear. Verify the ranking includes any higher-order axial modes that enter early.
Inputs
- First mode
- 7.8Hz
- Schroeder
- 127.4Hz
- Largest gap
- 7.8Hz
- Coincidences
- 1
Standing waves & modal spectrum
Illustrative scaleSeveral modal screening flags
LimitReview the ratio, coincidences, gaps and band counts before settling the dimensions.
Clear screenReviewMultiple flags
Input snapshot
- Length
- 22 m
- Width
- 3 m
- Height
- 2.8 m
- Measured or predicted RT60
- 0.75 s
- Air temperature
- 20 °C
Calculation breakdown
- Room volume
- 184.8 m³
- Sound speed
- 343.2 m/s
- H : W : L proportions
- 1 : 1.071 : 7.857
- Approximate Bolt area
- Outside
- Bonello density screen
- Clear
- Gap review threshold
- 20 Hz
| Mode | Family | Frequency |
|---|---|---|
| (1, 0, 0) | axial | 7.8 Hz |
| (2, 0, 0) | axial | 15.6 Hz |
| (3, 0, 0) | axial | 23.4 Hz |
| (4, 0, 0) | axial | 31.2 Hz |
| (5, 0, 0) | axial | 39 Hz |
| (6, 0, 0) | axial | 46.8 Hz |
| (7, 0, 0) | axial | 54.6 Hz |
| (0, 1, 0) | axial | 57.2 Hz |
| (1, 1, 0) | tangential | 57.73 Hz |
| (2, 1, 0) | tangential | 59.29 Hz |
| (0, 0, 1) | axial | 61.29 Hz |
| (1, 0, 1) | tangential | 61.78 Hz |
| (3, 1, 0) | tangential | 61.8 Hz |
| (8, 0, 0) | axial | 62.4 Hz |
| (2, 0, 1) | tangential | 63.24 Hz |
| (4, 1, 0) | tangential | 65.16 Hz |
| (3, 0, 1) | tangential | 65.6 Hz |
| (4, 0, 1) | tangential | 68.77 Hz |
| (5, 1, 0) | tangential | 69.23 Hz |
| (9, 0, 0) | axial | 70.2 Hz |
| (5, 0, 1) | tangential | 72.65 Hz |
| (6, 1, 0) | tangential | 73.91 Hz |
| (6, 0, 1) | tangential | 77.11 Hz |
| (10, 0, 0) | axial | 78 Hz |
| Band centre | Modes | Coincidence |
|---|---|---|
| 20 Hz | 0 | — |
| 25 Hz | 1 | — |
| 31.5 Hz | 1 | — |
| 40 Hz | 1 | — |
| 50 Hz | 2 | — |
| 63 Hz | 13 | Yes |
| 80 Hz | 13 | — |
| 100 Hz | 17 | — |
Rigid rectangular boundaries give ideal eigenfrequencies. Construction details, source and listener placement, surface impedance and damping affect measured levels. The Schroeder frequency is an approximate crossover.