Room modes example

Integer-ratio practice space

Room edges of 3, 6 and 9 metres produce exact harmonic overlaps across axes. Check the first 24 modes and the one-third-octave counts.

Inputs

Room geometry
Decay & air
First mode
19Hz
Schroeder
119.7Hz
Largest gap
9.5Hz
Coincidences
8

Standing waves & modal spectrum

Illustrative scale
Room plan and modal spectrumThe room plan illustrates standing-wave contours. Spectral lines show the first 18 modes with different heights and colours for their three families.ROOM PLANLOWEST 18 MODESL 9 mW 6 m19 Hz80.6 HzSchroeder 119.7 Hz
AxialTangentialOblique

Several modal screening flags

Limit

Review the ratio, coincidences, gaps and band counts before settling the dimensions.

Clear screenReviewMultiple flags

Calculation breakdown

Room volume
162 m³
Sound speed
342 m/s
H : W : L proportions
1 : 2 : 3
Approximate Bolt area
Outside
Bonello density screen
Review
Gap review threshold
20 Hz
Lowest 24 eigenmodes
ModeFamilyFrequency
(1, 0, 0)axial19 Hz
(0, 1, 0)axial28.5 Hz
(1, 1, 0)tangential34.26 Hz
(2, 0, 0)axial38 Hz
(2, 1, 0)tangential47.51 Hz
(0, 0, 1)axial57.01 Hz
(0, 2, 0)axial57.01 Hz
(3, 0, 0)axial57.01 Hz
(1, 0, 1)tangential60.09 Hz
(1, 2, 0)tangential60.09 Hz
(0, 1, 1)tangential63.74 Hz
(3, 1, 0)tangential63.74 Hz
(1, 1, 1)oblique66.51 Hz
(2, 0, 1)tangential68.51 Hz
(2, 2, 0)tangential68.51 Hz
(2, 1, 1)oblique74.21 Hz
(4, 0, 0)axial76.01 Hz
(0, 2, 1)tangential80.62 Hz
(3, 0, 1)tangential80.62 Hz
(3, 2, 0)tangential80.62 Hz
(4, 1, 0)tangential81.18 Hz
(1, 2, 1)oblique82.83 Hz
(0, 3, 0)axial85.51 Hz
(3, 1, 1)oblique85.51 Hz
Bonello band counts below Schroeder
Band centreModesCoincidence
20 Hz1—
25 Hz0—
31.5 Hz2—
40 Hz1—
50 Hz1—
63 Hz10Yes
80 Hz10Yes
100 Hz15Yes