RoomAcousticLab · Calculation record
Room modes example
Integer-ratio practice space
Room edges of 3, 6 and 9 metres produce exact harmonic overlaps across axes. Check the first 24 modes and the one-third-octave counts.
Inputs
- First mode
- 19Hz
- Schroeder
- 119.7Hz
- Largest gap
- 9.5Hz
- Coincidences
- 8
Standing waves & modal spectrum
Illustrative scaleSeveral modal screening flags
LimitReview the ratio, coincidences, gaps and band counts before settling the dimensions.
Clear screenReviewMultiple flags
Input snapshot
- Length
- 9 m
- Width
- 6 m
- Height
- 3 m
- Measured or predicted RT60
- 0.58 s
- Air temperature
- 18 °C
Calculation breakdown
- Room volume
- 162 m³
- Sound speed
- 342 m/s
- H : W : L proportions
- 1 : 2 : 3
- Approximate Bolt area
- Outside
- Bonello density screen
- Review
- Gap review threshold
- 20 Hz
| Mode | Family | Frequency |
|---|---|---|
| (1, 0, 0) | axial | 19 Hz |
| (0, 1, 0) | axial | 28.5 Hz |
| (1, 1, 0) | tangential | 34.26 Hz |
| (2, 0, 0) | axial | 38 Hz |
| (2, 1, 0) | tangential | 47.51 Hz |
| (0, 0, 1) | axial | 57.01 Hz |
| (0, 2, 0) | axial | 57.01 Hz |
| (3, 0, 0) | axial | 57.01 Hz |
| (1, 0, 1) | tangential | 60.09 Hz |
| (1, 2, 0) | tangential | 60.09 Hz |
| (0, 1, 1) | tangential | 63.74 Hz |
| (3, 1, 0) | tangential | 63.74 Hz |
| (1, 1, 1) | oblique | 66.51 Hz |
| (2, 0, 1) | tangential | 68.51 Hz |
| (2, 2, 0) | tangential | 68.51 Hz |
| (2, 1, 1) | oblique | 74.21 Hz |
| (4, 0, 0) | axial | 76.01 Hz |
| (0, 2, 1) | tangential | 80.62 Hz |
| (3, 0, 1) | tangential | 80.62 Hz |
| (3, 2, 0) | tangential | 80.62 Hz |
| (4, 1, 0) | tangential | 81.18 Hz |
| (1, 2, 1) | oblique | 82.83 Hz |
| (0, 3, 0) | axial | 85.51 Hz |
| (3, 1, 1) | oblique | 85.51 Hz |
| Band centre | Modes | Coincidence |
|---|---|---|
| 20 Hz | 1 | — |
| 25 Hz | 0 | — |
| 31.5 Hz | 2 | — |
| 40 Hz | 1 | — |
| 50 Hz | 1 | — |
| 63 Hz | 10 | Yes |
| 80 Hz | 10 | Yes |
| 100 Hz | 15 | Yes |
Rigid rectangular boundaries give ideal eigenfrequencies. Construction details, source and listener placement, surface impedance and damping affect measured levels. The Schroeder frequency is an approximate crossover.