RoomAcousticLab · Calculation record
Reverberation time example
Gymnasium panel capacity
A tall gym can only accept panels on a limited part of its side walls. Compare the 85-square-metre allowance with the area needed for a 1.2-second Sabine target.
Inputs
Use absorption coefficients for the same frequency band.
- Sabine
- 5.182s
- Eyring
- 4.999s
- Fitzroy
- 5.179s
- Panel area
- —
Room section & absorption
Illustrative scaleTarget infeasible on selected faces
LimitEven replacing both faces in this orientation cannot reach the target with the selected panel and model.
Target metPanels neededInfeasible
Input snapshot
- Length
- 28 m
- Width
- 16 m
- Height
- 8 m
- End walls αx
- 0.05
- Side walls αy
- 0.06
- Floor / ceiling αz
- 0.08
- Air temperature
- 20 °C
- Target RT60
- 1.2 s
- Size panels with
- Sabine
- Treatment surface
- Side walls · y
- Panel absorption α
- 0.82
- Available area
- 85 m²
Calculation breakdown
- Room volume
- 3,584 m³
- Room surface area
- 1,600 m²
- Equivalent absorption area
- 111.36 m²
- Mean absorption α
- 0.0696
- Treatment sizing model
- Sabine
- Baseline α of selected pair
- 0.06
- Selected pair area
- 448 m²
- Decay before treatment
- 5.182 s
- Decay with proposed area
- No feasible area
- Best decay within allowance
- 3.279 s
Use Sabine in the low-absorption regime, Eyring for a more evenly distributed field, and Fitzroy when opposite pairs differ. The models omit air absorption, leakage and non-diffuse geometry. Measured decay and installed band coefficients should drive a final specification.