Reverberation time example

Library ceiling treatment

An open reading room already has absorptive shelving and flooring. Check whether the current estimate meets a 0.85-second target before specifying extra ceiling treatment.

Inputs

Room geometry
Surface absorption
Treatment plan

Use absorption coefficients for the same frequency band.

Sabine
0.567s
Eyring
0.481s
Fitzroy
0.489s
Panel area
0m²

Room section & absorption

Illustrative scale
Dimensioned room and treatment surfaceThe selected pair of surfaces is highlighted beside its absorption coefficient. A sample reflection links room geometry to decay.L 12 mW 9 mH 3.3 mPAIR ABSORPTIONαx 0.23αy 0.26αz 0.31PANEL COVERAGE0% of pair
TreatmentReflectionsDimensions

Decay target already met

Pass

The selected model is at or below the entered RT60. The required added area is zero.

Target metPanels neededInfeasible

Calculation breakdown

Room volume
356.4 m³
Room surface area
354.6 m²
Equivalent absorption area
101.21 m²
Mean absorption α
0.2854
Treatment sizing model
Eyring
Baseline α of selected pair
0.31
Selected pair area
216 m²
Decay before treatment
0.481 s
Decay with proposed area
0.481 s
Best decay within allowance
0.481 s