RoomAcousticLab · Calculation record
Reverberation time example
Untreated classroom
A hard-finished teaching room needs a shorter decay for speech. Estimate the ceiling coverage needed to aim for 0.60 seconds in the chosen band.
Inputs
Use absorption coefficients for the same frequency band.
- Sabine
- 1.41s
- Eyring
- 1.345s
- Fitzroy
- 1.371s
- Panel area
- 24.45m²
Room section & absorption
Illustrative scaleTarget reachable with panels
ReviewThe calculated area fits the entered allowance. Verify the installed absorption for the same band.
Target metPanels neededInfeasible
Input snapshot
- Length
- 8 m
- Width
- 6 m
- Height
- 3 m
- End walls αx
- 0.07
- Side walls αy
- 0.09
- Floor / ceiling αz
- 0.1
- Air temperature
- 20 °C
- Target RT60
- 0.6 s
- Size panels with
- Eyring
- Treatment surface
- Floor / ceiling · z
- Panel absorption α
- 0.85
- Available area
- 38 m²
Calculation breakdown
- Room volume
- 144 m³
- Room surface area
- 180 m²
- Equivalent absorption area
- 16.44 m²
- Mean absorption α
- 0.0913
- Treatment sizing model
- Eyring
- Baseline α of selected pair
- 0.1
- Selected pair area
- 96 m²
- Decay before treatment
- 1.345 s
- Decay with proposed area
- 0.6 s
- Best decay within allowance
- 0.448 s
Use Sabine in the low-absorption regime, Eyring for a more evenly distributed field, and Fitzroy when opposite pairs differ. The models omit air absorption, leakage and non-diffuse geometry. Measured decay and installed band coefficients should drive a final specification.