Reverberation time example

Rehearsal room with uneven absorption

Two wall orientations reflect much more energy than the treated floor and ceiling. Compare Fitzroy with Eyring and test whether side-wall treatment can balance the decay.

Inputs

Room geometry
Surface absorption
Treatment plan

Use absorption coefficients for the same frequency band.

Sabine
0.612s
Eyring
0.526s
Fitzroy
1.146s
Panel area
5.25m²

Room section & absorption

Illustrative scale
Dimensioned room and treatment surfaceThe selected pair of surfaces is highlighted beside its absorption coefficient. A sample reflection links room geometry to decay.L 10 mW 7 mH 4 mPAIR ABSORPTIONαx 0.13αy 0.06αz 0.44PANEL COVERAGE6.6% of pair
TreatmentReflectionsDimensions

Target reachable with panels

Review

The calculated area fits the entered allowance. Verify the installed absorption for the same band.

Target metPanels neededInfeasible

Calculation breakdown

Room volume
280 m³
Room surface area
276 m²
Equivalent absorption area
73.68 m²
Mean absorption α
0.267
Treatment sizing model
Fitzroy
Baseline α of selected pair
0.06
Selected pair area
80 m²
Decay before treatment
1.146 s
Decay with proposed area
0.78 s
Best decay within allowance
0.488 s