Indoor sound field example

Lecture room ceiling replacement

A partial replacement adds absorption without changing the source or receiver location. Compare the prediction at the listener with the diffuse-only change.

Inputs

Room & source
Absorption change
Sound level
73.3dB
Critical dist.
1.38m
Direct share
2.9%
Level drop
1.96dB

Direct and reflected energy paths

Illustrative scale
Room sound paths and critical distanceTwo reflected rays and a direct ray reach the receiver. A dashed marker shows the critical distance inside the drawable range.SOURCERECEIVERr 8 mDᶜ 1.38 m
Direct fieldReflectionsReceiver

Small receiver reserve

Review

There is less than 3 dB of modelled reserve against the entered target.

≥ 3 dB reserveReviewOver target

Calculation breakdown

Room constant R
96.27 m²
Direct level
57.95 dB
Reverberant level
73.19 dB
Receiver regime
Reverberant dominated
Treated mean absorption α
0.2466
Treated receiver level
71.35 dB
Diffuse-only level drop
2.04 dB