Outdoor noise setback example

Roof fan at the property line

Use a half-space screening assumption for one rooftop fan. Estimate the property-line level at 28 metres and solve the distance to the entered limit.

Inputs

Source geometry
Propagation & receiver
Receiver SPL
60dB
Setback
39.5m
Air loss
0.06dB
Limit margin
-3.02dB

Source geometry & receiver setback

Illustrative scale
Outdoor source and property-line pathThe path from the selected point or line source is drawn to the receiver. The vertical dashed marker indicates the calculated setback within the schematic scale.POINT SOURCERECEIVERr 28 mSetback 39.5 m60 dB
Sound pathReceiverTarget line

Property-line limit exceeded

Limit

The modelled value falls on the wrong side of the entered target.

≥ 3 dB reserve0–3 dB reserveOver limit

Calculation breakdown

Geometrical spreading loss
39.94 dB
Directivity gain
3.01 dB
Identical-source addition
0 dB
Entered property-line limit
57 dB
Setback search result
Solved inside model range