RoomAcousticLab · Calculation record
Outdoor noise setback example
Setback beyond the model range
A high line power combined with a very restrictive limit leaves no solution inside the 100-kilometre search envelope. Inspect the explicit out-of-range result.
Inputs
- Receiver SPL
- 109dB
- Setback
- —
- Air loss
- 0dB
- Limit margin
- -68.98dB
Source geometry & receiver setback
Illustrative scaleSetback exceeds the model range
LimitThe entered limit is still exceeded at the upper search bound of 100 km.
≥ 3 dB reserve0–3 dB reserveOver limit
Input snapshot
- Source type
- Infinite line
- Sound power per unit length
- 125 dB/m
- Directivity Q
- 2 · Half space
- Identical sources
- 3
- Source addition
- Incoherent · energy
- Receiver distance
- 60 m
- Air attenuation
- 0 dB/km
- Property-line limit
- 40 dB
Calculation breakdown
- Geometrical spreading loss
- 23.8 dB
- Directivity gain
- 3.01 dB
- Identical-source addition
- 4.77 dB
- Entered property-line limit
- 40 dB
- Setback search result
- Beyond 100,000 m
Setback is solved between 0.1 m and 100 km. This model considers divergence and the entered air loss. A site study can include ground impedance, shielding, weather, reflections, background and source spectra as required by the governing method.