Indoor sound field example

Test cell with a harder ceiling

Replacing an existing absorptive finish with a harder one is a deliberate adverse case. Check how the sign of the predicted level change reverses.

Inputs

Room & source
Absorption change
Sound level
84.5dB
Critical dist.
1.3m
Direct share
15.9%
Level drop
-3.04dB

Direct and reflected energy paths

Illustrative scale
Room sound paths and critical distanceTwo reflected rays and a direct ray reach the receiver. A dashed marker shows the critical distance inside the drawable range.SOURCERECEIVERr 3 mDᶜ 1.3 m
Direct fieldReflectionsReceiver

Small receiver reserve

Review

There is less than 3 dB of modelled reserve against the entered target.

≥ 3 dB reserveReviewOver target

Calculation breakdown

Room constant R
42.78 m²
Direct level
76.48 dB
Reverberant level
83.71 dB
Receiver regime
Reverberant dominated
Treated mean absorption α
0.15
Treated receiver level
87.5 dB
Diffuse-only level drop
-3.43 dB