Indoor sound field example

Absorptive workshop ceiling

A machine is measured at a receiver across a workshop. Estimate how much a ceiling finish change lowers the total level and the diffuse portion.

Inputs

Room & source
Absorption change
Sound level
90.6dB
Critical dist.
1.36m
Direct share
4.9%
Level drop
4.31dB

Direct and reflected energy paths

Illustrative scale
Room sound paths and critical distanceTwo reflected rays and a direct ray reach the receiver. A dashed marker shows the critical distance inside the drawable range.SOURCERECEIVERr 6 mDᶜ 1.36 m
Direct fieldReflectionsReceiver

Receiver target exceeded

Limit

The modelled value falls on the wrong side of the entered target.

≥ 3 dB reserveReviewOver target

Calculation breakdown

Room constant R
46.36 m²
Direct level
77.46 dB
Reverberant level
90.36 dB
Receiver regime
Reverberant dominated
Treated mean absorption α
0.2871
Treated receiver level
86.27 dB
Diffuse-only level drop
4.7 dB