Motor mount stiffness at running speed
The isolator supports 82 kg with a quoted vertical stiffness of 163 kN/m and a 520 N dynamic forcing amplitude.
Live results
Mount response & transmissibility curve- Natural freq.
- 7.0959Hz
- Force ratio
- 0.10447×
- Transmitted
- 54.327N
- Isolation
- 89.553%
Force isolation cutover
Within screenThe mount transmits less force than the input amplitude.
Editable case inputs
Calculation details
| Vertical mount stiffness | 163,000 N/m |
|---|---|
| Equivalent static deflection | 4.93341 mm |
| Forcing frequency | 24.5 Hz |
| Equivalent forcing speed | 1,470 RPM |
| Frequency ratio r | 3.4527 |
| Unity-transmissibility cutover | 10.0351 Hz |
What to check
The forcing frequency is above the unity cutover. Compare force ratio and transmitted amplitude per mount.
Model & assumptions
Enter the supported mass for one mount and its vertical stiffness or loaded static deflection. For a single harmonic force, transmitted amplitude is T times the excitation. Negative isolation indicates amplification.
This single-mode model assumes a linear spring and viscous damping. At r = √2 the force ratio is unity. Include support flexibility, coupled modes and the start-up speed range when assessing a real installation.
Methodology and references ↗RotorVibLab · SI · Engineering calculation
Motor mount stiffness at running speed
fn = √(k/m)/(2π) = √(g/δst)/(2π) · r = fd/fn · T = √[(1+(2ζr)²)/((1−r²)²+(2ζr)²)]
Operating inputs
| Mount definition | Vertical stiffness |
|---|---|
| Mass per mount | 82 kg |
| Vertical stiffness k | 163,000 N/m |
| Damping ratio ζ | 0.08 |
| Frequency convention | Hertz (Hz) |
| Forcing frequency | 24.5 Hz |
| Input force amplitude | 520 N |
Results
| Natural freq. | 7.09589 Hz |
|---|---|
| Force ratio | 0.104475 × |
| Transmitted | 54.327 N |
| Isolation | 89.5525 % |
| Vertical mount stiffness | 163,000 N/m |
| Equivalent static deflection | 4.93341 mm |
| Forcing frequency | 24.5 Hz |
| Equivalent forcing speed | 1,470 RPM |
| Frequency ratio r | 3.4527 |
| Unity-transmissibility cutover | 10.0351 Hz |
Force isolation cutover. The mount transmits less force than the input amplitude.