A 22 mm static-deflection spring mount sees a 3.4 Hz component during run-up with only 4% viscous damping.
Live results
Mount response & transmissibility curve- Natural freq.
- 3.3602Hz
- Force ratio
- 11.89×
- Transmitted
- 4,042.8N
- Isolation
- -1,089%
Force isolation cutover
Outside screenThe mount amplifies the input force. The isolation region starts above r = √2.
Editable case inputs
Calculation details
| Vertical mount stiffness | 55,719.6 N/m |
|---|---|
| Equivalent static deflection | 22 mm |
| Forcing frequency | 3.4 Hz |
| Equivalent forcing speed | 204 RPM |
| Frequency ratio r | 1.01184 |
| Unity-transmissibility cutover | 4.75208 Hz |
What to check
Inspect the amber point near the resonance peak. Negative isolation means the transmitted force exceeds the forcing amplitude.
Model & assumptions
Enter the supported mass for one mount and its vertical stiffness or loaded static deflection. For a single harmonic force, transmitted amplitude is T times the excitation. Negative isolation indicates amplification.
This single-mode model assumes a linear spring and viscous damping. At r = √2 the force ratio is unity. Include support flexibility, coupled modes and the start-up speed range when assessing a real installation.
Methodology and references ↗RotorVibLab · SI · Engineering calculation
Soft spring mount near startup resonance
fn = √(k/m)/(2π) = √(g/δst)/(2π) · r = fd/fn · T = √[(1+(2ζr)²)/((1−r²)²+(2ζr)²)]
Operating inputs
| Mount definition | Static deflection |
|---|---|
| Mass per mount | 125 kg |
| Static deflection δst | 22 mm |
| Damping ratio ζ | 0.04 |
| Frequency convention | Hertz (Hz) |
| Forcing frequency | 3.4 Hz |
| Input force amplitude | 340 N |
Results
| Natural freq. | 3.36023 Hz |
|---|---|
| Force ratio | 11.8905 × |
| Transmitted | 4,042.76 N |
| Isolation | -1,089.05 % |
| Vertical mount stiffness | 55,719.6 N/m |
| Equivalent static deflection | 22 mm |
| Forcing frequency | 3.4 Hz |
| Equivalent forcing speed | 204 RPM |
| Frequency ratio r | 1.01184 |
| Unity-transmissibility cutover | 4.75208 Hz |
Force isolation cutover. The mount amplifies the input force. The isolation region starts above r = √2.