RotorVibLab
Menu

Soft spring mount near startup resonance

A 22 mm static-deflection spring mount sees a 3.4 Hz component during run-up with only 4% viscous damping.

Units
Edit inputs ↓

Live results

Mount response & transmissibility curve
Force ratio
11.89×
Transmitted
4,042.8N
Isolation
-1,089%
Force ratio TDamping ζ 0.046+101√23.25 rfn 3.36 HzOperating r 1.012

Force isolation cutover

Outside screen
Amplificationr = √2Isolation

The mount amplifies the input force. The isolation region starts above r = √2.

Editable case inputs

Mount parameters
kg
mm
Forcing conditions
Hz
N

Calculation details

Vertical mount stiffness55,719.6 N/m
Equivalent static deflection22 mm
Forcing frequency3.4 Hz
Equivalent forcing speed204 RPM
Frequency ratio r1.01184
Unity-transmissibility cutover4.75208 Hz

What to check

Inspect the amber point near the resonance peak. Negative isolation means the transmitted force exceeds the forcing amplitude.

Model & assumptions

fn = √(k/m)/(2π) = √(g/δst)/(2π) · r = fd/fn · T = √[(1+(2ζr)²)/((1−r²)²+(2ζr)²)]

Enter the supported mass for one mount and its vertical stiffness or loaded static deflection. For a single harmonic force, transmitted amplitude is T times the excitation. Negative isolation indicates amplification.

This single-mode model assumes a linear spring and viscous damping. At r = √2 the force ratio is unity. Include support flexibility, coupled modes and the start-up speed range when assessing a real installation.

Methodology and references ↗