Mount at the unity-transmission cutover

A 44 kg test mass is supported by a spring with a 5 Hz natural frequency. The forcing tone is √2 times fn.

Units
Edit inputs ↓

Live results

Mount response & transmissibility curve
Force ratio
1×
Transmitted
100N
Isolation
-2.22e-14%
Force ratio TDamping ζ 0.166+101√23.25 rfn 5 HzOperating r 1.414

Force isolation cutover

Outside screen
Amplificationr = √2Isolation

The mount amplifies the input force. The isolation region starts above r = √2.

Editable case inputs

Mount parameters
kg
N/m
Forcing conditions
Hz
N

Calculation details

Vertical mount stiffness43,426.3 N/m
Equivalent static deflection9.93621 mm
Forcing frequency7.07107 Hz
Equivalent forcing speed424.264 RPM
Frequency ratio r1.41421
Unity-transmissibility cutover7.07107 Hz

What to check

The boundary should read unity within the selected numerical precision. A higher frequency moves the marker into force isolation.

Model & assumptions

fn = √(k/m)/(2π) = √(g/δst)/(2π) · r = fd/fn · T = √[(1+(2ζr)²)/((1−r²)²+(2ζr)²)]

Enter the supported mass for one mount and its vertical stiffness or loaded static deflection. For a single harmonic force, transmitted amplitude is T times the excitation. Negative isolation indicates amplification.

This single-mode model assumes a linear spring and viscous damping. At r = √2 the force ratio is unity. Include support flexibility, coupled modes and the start-up speed range when assessing a real installation.