Single-plane fan trim from a field trial
A 12 g weight is added at 120° on the fan correction radius. Initial vibration is 4.6 mm/s at 22° and the trial run reads 5.2 mm/s at 95°.
Live results
Correction planes & polar vectors- Trim mass
- 9.4372g
- Trim angle
- 178.23°
- Model residual
- 1.986e-15mm/s RMS
- Trial change
- 5.8492mm/s RMS
Post-trim vibration
Reference onlyThe linear model predicts the residual. Enter a post-trim reading to verify the target.
Editable case inputs
Calculation details
| Influence magnitude | 0.487432 mm/s per g |
|---|---|
| Influence phase | 23.7701 ° |
| Measured post-trim RMS | — |
| Verification target | 1 mm/s RMS |
What to check
Read the correction as a replacement for the trial mass at the same radius. Use its predicted residual to check the algebra before measuring the new run.
Model & assumptions
Use maximum service speed and the selected grade for a rigid rotor. Allocate the allowable total with the plane fraction appropriate to the balance arrangement. Select vector trim for a fixed-radius trial with a repeatable phase reference and the same running speed.
ISO 21940-11 continues the rigid-rotor balance framework from ISO 1940-1. Allocate limits using the approved balance plan and verify single-plane trim with an independent post-trim reading. Use machine procedures for trial-weight placement and retention.
Methodology and references ↗RotorVibLab · SI · Engineering calculation
Single-plane fan trim from a field trial
eₚₑᵣ = 1,000·G/ω · Uₚₑᵣ = M·eₚₑᵣ · α = (V₁−V₀)/Wt · Wc = −V₀/α
Operating inputs
| Calculation | Single-plane vector trim |
|---|---|
| Initial 1× vibration | 4.6 mm/s RMS |
| Initial phase | 22 ° |
| Trial mass Wt | 12 g |
| Trial mass angle | 120 ° |
| Trial 1× vibration | 5.2 mm/s RMS |
| Trial phase | 95 ° |
| Measured post-trim | — |
| Post-trim RMS target | 1 mm/s RMS |
Results
| Trim mass | 9.43722 g |
|---|---|
| Trim angle | 178.23 ° |
| Model residual | 1.986e-15 mm/s RMS |
| Trial change | 5.84918 mm/s RMS |
| Influence magnitude | 0.487432 mm/s per g |
| Influence phase | 23.7701 ° |
| Measured post-trim RMS | — |
| Verification target | 1 mm/s RMS |
Post-trim vibration. The linear model predicts the residual. Enter a post-trim reading to verify the target.