RotorVibLab
Menu

Single-plane fan trim from a field trial

A 12 g weight is added at 120° on the fan correction radius. Initial vibration is 4.6 mm/s at 22° and the trial run reads 5.2 mm/s at 95°.

Units
Edit inputs ↓

Live results

Correction planes & polar vectors
Trim angle
178.23°
Model residual
1.986e-15mm/s RMS
Trial change
5.8492mm/s RMS
90°270°180°0°Trial response vectorsInitial V₀4.6 mm/s RMSTrial V₁5.2 mm/s RMSChange ΔV5.849 mm/s RMSTrim mass9.437 gTrim phase178.2 °

Post-trim vibration

Reference only
Residual lowRMS targetAbove target

The linear model predicts the residual. Enter a post-trim reading to verify the target.

Editable case inputs

Balance method
Single-plane trial run
mm/s RMS
°
g
°
mm/s RMS
°
mm/s RMS
mm/s RMS

Keep the sensor reference, direction of rotation and trial radius the same between runs.

Calculation details

Influence magnitude0.487432 mm/s per g
Influence phase23.7701 °
Measured post-trim RMS—
Verification target1 mm/s RMS

What to check

Read the correction as a replacement for the trial mass at the same radius. Use its predicted residual to check the algebra before measuring the new run.

Model & assumptions

eₚₑᵣ = 1,000·G/ω · Uₚₑᵣ = M·eₚₑᵣ · α = (V₁−V₀)/Wt · Wc = −V₀/α

Use maximum service speed and the selected grade for a rigid rotor. Allocate the allowable total with the plane fraction appropriate to the balance arrangement. Select vector trim for a fixed-radius trial with a repeatable phase reference and the same running speed.

ISO 21940-11 continues the rigid-rotor balance framework from ISO 1940-1. Allocate limits using the approved balance plan and verify single-plane trim with an independent post-trim reading. Use machine procedures for trial-weight placement and retention.

Methodology and references ↗