Vibration Isolator Transmissibility Calculator
Find mount natural frequency, static deflection and the transmitted force across resonance and the isolation cutover.
Live results
Mount response & transmissibility curve- Natural freq.
- 8.4908Hz
- Force ratio
- 0.11727×
- Transmitted
- 49.255N
- Isolation
- 88.273%
Force isolation cutover
Within screenThe mount transmits less force than the input amplitude.
Operating inputs
Calculation details
| Vertical mount stiffness | 185,000 N/m |
|---|---|
| Equivalent static deflection | 3.44558 mm |
| Forcing frequency | 29.5 Hz |
| Equivalent forcing speed | 1,770 RPM |
| Frequency ratio r | 3.47434 |
| Unity-transmissibility cutover | 12.0078 Hz |
Model & assumptions
Enter the supported mass for one mount and its vertical stiffness or loaded static deflection. For a single harmonic force, transmitted amplitude is T times the excitation. Negative isolation indicates amplification.
This single-mode model assumes a linear spring and viscous damping. At r = √2 the force ratio is unity. Include support flexibility, coupled modes and the start-up speed range when assessing a real installation.
Methodology and references ↗RotorVibLab · SI · Engineering calculation
Vibration Isolator Transmissibility Calculator
fn = √(k/m)/(2π) = √(g/δst)/(2π) · r = fd/fn · T = √[(1+(2ζr)²)/((1−r²)²+(2ζr)²)]
Operating inputs
| Mount definition | Vertical stiffness |
|---|---|
| Mass per mount | 65 kg |
| Vertical stiffness k | 185,000 N/m |
| Damping ratio ζ | 0.12 |
| Frequency convention | Hertz (Hz) |
| Forcing frequency | 29.5 Hz |
| Input force amplitude | 420 N |
Results
| Natural freq. | 8.49081 Hz |
|---|---|
| Force ratio | 0.117275 × |
| Transmitted | 49.2554 N |
| Isolation | 88.2725 % |
| Vertical mount stiffness | 185,000 N/m |
| Equivalent static deflection | 3.44558 mm |
| Forcing frequency | 29.5 Hz |
| Equivalent forcing speed | 1,770 RPM |
| Frequency ratio r | 3.47434 |
| Unity-transmissibility cutover | 12.0078 Hz |
Force isolation cutover. The mount transmits less force than the input amplitude.