Flash Steam & Condensate Recovery Calculator
Calculate flash fraction across a pressure drop, usable flash steam, return heat credit and annual fuel and treatment savings.
Inputs
Inputs
- High-pressure condensate
- 3,500 lb/hr
- Source pressure P₁
- 125 psig
- Receiver pressure P₂
- 10 psig
- Flash steam utilization
- 90 %
- Liquid condensate returned
- 85 %
- Cold make-up temperature
- 68 °F
- Boiler efficiency
- 82 %
- Annual operating time
- 6,500 h/yr
- Currency
- USD
- Energy price
- 8.5 USD/MMBtu
- Water + treatment price
- 4 USD/1,000 gal
Calculation results
- Flash steam fraction
- 12.28%
- Flash steam generated
- 429.9lb/hr
- Flash steam used
- 386.9lb/hr
- Post-flash liquid
- 3,070.1lb/hr
- Condensate returned
- 2,609.6lb/hr
- Original inlet mass returned
- 74.56%
- Inlet heat recovered by liquid return
- 44.34%
- Flash latent heat credit
- 368,521.93Btu/h
- Return sensible heat credit
- 448,073.09Btu/h
- Source liquid enthalpy
- 324.81Btu/lb
- Receiver liquid enthalpy
- 207.82Btu/lb
- Receiver latent heat
- 952.49Btu/lb
- Annual fuel energy avoided
- 6,473MMBtu/yr
- Annual fuel savings
- 55,021USD/yr
- Annual water and treatment savings
- 8,130USD/yr
- Combined annual savings
- 63,151USD/yr
Calculation basis
- Isenthalpic flash
f = (h_f1 − h_f2)/h_fg2; m_flash = m_in·f - Heat credit
Q_flash = m_flash,used·h_fg2; Q_return = m_return·(h_f2 − h_makeup) - Annual savings
Savings = hours·[(Q_flash + Q_return)·tariff/η + water volume rate·water tariff]
Formulas and assumptions
Isenthalpic flash
f = (h_f1 − h_f2)/h_fg2; m_flash = m_in·f
The inlet is saturated liquid at P₁. Flow leaves the receiver as saturated vapor and saturated liquid at P₂.
Heat credit
Q_flash = m_flash,used·h_fg2; Q_return = m_return·(h_f2 − h_makeup)
The liquid credit percentage divides returned heat by all inlet sensible heat above cold make-up. Vapor credit uses latent heat, with no liquid return assumed from the vapor user.
Annual savings
Savings = hours·[(Q_flash + Q_return)·tariff/η + water volume rate·water tariff]
Water and treatment savings apply to returned liquid at an accounting density of 1,000 kg/m³. Enter the combined water and treatment tariff.
Worked examples