7 bar g to a 1 bar g receiver
A pressurized receiver replaces the atmospheric receiver in the 250 kg/h tutorial case.
Inputs
Inputs
- High-pressure condensate
- 551.2 lb/hr
- Source pressure P₁
- 101.53 psig
- Receiver pressure P₂
- 14.5 psig
- Flash steam utilization
- 100 %
- Liquid condensate returned
- 90 %
- Cold make-up temperature
- 68 °F
- Boiler efficiency
- 82 %
- Annual operating time
- 6,500 h/yr
- Currency
- USD
- Energy price
- 8.5 USD/MMBtu
- Water + treatment price
- 4 USD/1,000 gal
Calculation results
- Flash steam fraction
- 9.8%
- Flash steam generated
- 54lb/hr
- Flash steam used
- 54lb/hr
- Post-flash liquid
- 497.1lb/hr
- Condensate returned
- 447.4lb/hr
- Original inlet mass returned
- 81.18%
- Inlet heat recovered by liquid return
- 53.7%
- Flash latent heat credit
- 51,122.09Btu/h
- Return sensible heat credit
- 81,088.74Btu/h
- Source liquid enthalpy
- 310.11Btu/lb
- Receiver liquid enthalpy
- 217.36Btu/lb
- Receiver latent heat
- 946.25Btu/lb
- Annual fuel energy avoided
- 1,048MMBtu/yr
- Annual fuel savings
- 8,908USD/yr
- Annual water and treatment savings
- 1,394USD/yr
- Combined annual savings
- 10,302USD/yr
Calculation basis
- Isenthalpic flash
f = (h_f1 − h_f2)/h_fg2; m_flash = m_in·f - Heat credit
Q_flash = m_flash,used·h_fg2; Q_return = m_return·(h_f2 − h_makeup) - Annual savings
Savings = hours·[(Q_flash + Q_return)·tariff/η + water volume rate·water tariff]
Check the original case
The flash fraction falls to about 9.8% as the higher-pressure liquid can retain more sensible heat.
- Flash steam fraction9.8 %
- Flash steam used54 lb/hr
- Condensate returned447.4 lb/hr
- Combined annual savings10,302 USD/yr
Formulas and assumptions
Isenthalpic flash
f = (h_f1 − h_f2)/h_fg2; m_flash = m_in·f
The inlet is saturated liquid at P₁. Flow leaves the receiver as saturated vapor and saturated liquid at P₂.
Heat credit
Q_flash = m_flash,used·h_fg2; Q_return = m_return·(h_f2 − h_makeup)
The liquid credit percentage divides returned heat by all inlet sensible heat above cold make-up. Vapor credit uses latent heat, with no liquid return assumed from the vapor user.
Annual savings
Savings = hours·[(Q_flash + Q_return)·tariff/η + water volume rate·water tariff]
Water and treatment savings apply to returned liquid at an accounting density of 1,000 kg/m³. Enter the combined water and treatment tariff.
Worked examples
Open a case to edit its inputs.