7 bar g to a 1 bar g receiver

A pressurized receiver replaces the atmospheric receiver in the 250 kg/h tutorial case.

Inputs

lb/hr
psig
psig
%
%
Percentage of post-flash liquid flow.
°F
%
h/yr
Currency labels your tariff and savings. Enter local prices.
USD/MMBtu
USD/1,000 gal
Flash vessel phase separation
Flash vessel phase separationFLASH 9.8 %. FLASH USED 54 lb/hr. RETURN FLOW 447.4 lb/hr. YEAR SAVINGS 10.3K USD/yrFLASH9.8%FLASH USED54lb/hrRETURN FLOW447.4lb/hrYEAR SAVINGS10.3KUSD/yrFLASH VESSEL14.5 psigCONDENSATE IN101.53 psigFLASH VAPORLIQUID RETURN81.18% of inletVapor share of inlet mass9.8% flash0%Liquid + vapor = inlet100%
Live steam / heatCondensate / waterDischarge / loss

Calculation results

Flash steam fraction
9.8%
Flash steam generated
54lb/hr
Flash steam used
54lb/hr
Post-flash liquid
497.1lb/hr
Condensate returned
447.4lb/hr
Original inlet mass returned
81.18%
Inlet heat recovered by liquid return
53.7%
Flash latent heat credit
51,122.09Btu/h
Return sensible heat credit
81,088.74Btu/h
Source liquid enthalpy
310.11Btu/lb
Receiver liquid enthalpy
217.36Btu/lb
Receiver latent heat
946.25Btu/lb
Annual fuel energy avoided
1,048MMBtu/yr
Annual fuel savings
8,908USD/yr
Annual water and treatment savings
1,394USD/yr
Combined annual savings
10,302USD/yr

Check the original case

The flash fraction falls to about 9.8% as the higher-pressure liquid can retain more sensible heat.

  • Flash steam fraction9.8 %
  • Flash steam used54 lb/hr
  • Condensate returned447.4 lb/hr
  • Combined annual savings10,302 USD/yr

Formulas and assumptions

Isenthalpic flash

f = (h_f1 − h_f2)/h_fg2; m_flash = m_in·f

The inlet is saturated liquid at P₁. Flow leaves the receiver as saturated vapor and saturated liquid at P₂.

Heat credit

Q_flash = m_flash,used·h_fg2; Q_return = m_return·(h_f2 − h_makeup)

The liquid credit percentage divides returned heat by all inlet sensible heat above cold make-up. Vapor credit uses latent heat, with no liquid return assumed from the vapor user.

Annual savings

Savings = hours·[(Q_flash + Q_return)·tariff/η + water volume rate·water tariff]

Water and treatment savings apply to returned liquid at an accounting density of 1,000 kg/m³. Enter the combined water and treatment tariff.