Increase the clear web height and reduce thickness. The web can be slender even when the selected compression flange is compact.
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
ANSI/AISC 360-22B4.1b
Inputs
LRFD
Use loads and strengths from the selected method. Re-enter values after switching methods.
Section and neutral axes
Yield reference
Gross area
34.875in²
Inertia Iₓ
17,590.5in⁴
Plastic Zₓ
720.563in³
Unit weight
118.672lb/ft
The ENA is the elastic centroidal axis. The PNA divides the area in half for uniform material. The lines coincide in symmetric sections.
Calculation results
Limit state
Demand
Reference
Use
Plastic yield reference
1,620 kip-ft
2,702.109 kip-ft
60%
Compression element compactness
Element
λ
λₚ
λᵣ
Class
Flange
8
9.152
16.178
Compact
Web
172.8
90.553
137.274
Slender
Calculation values
ENA above bottom
27.75 in
PNA above bottom
27.75 in
Inertia Iᵧ
216.137 in⁴
Elastic Sₓ,top
633.892 in³
Elastic Sₓ,bot
633.892 in³
Radius of gyration rₓ
22.459 in
Radius of gyration rᵧ
2.489 in
First yield Mᵧ
2,641.216 kip-ft
Plastic Mₚ
3,002.344 kip-ft
Yield reference · LRFD
2,702.109 kip-ft
Yield reference · ASD
1,797.811 kip-ft
SteelBeamLab / AISC 360-22 B4.1b
Thin-web I-girder compactness screen
LRFD · US customary
The yield utilization is a reference ceiling. Verify Chapter F local buckling and LTB, shear, welds, stiffeners, and fabrication before sizing a member.
Entered values
Section geometry
Built-up I-girder
Compression face
Top flange
Steel yield stress Fᵧ
50 ksi
Required moment Mᵣ
1,620 kip-ft
Top flange width
12 in
Top flange thickness
0.75 in
Bottom flange width
12 in
Bottom flange thickness
0.75 in
Clear web height h
54 in
Web thickness tᵥ
0.313 in
Key results
Gross area
34.875in²
Inertia Iₓ
17,590.5in⁴
Plastic Zₓ
720.563in³
Unit weight
118.672lb/ft
Limit-state screening
Limit state
Demand
Reference
Use
Plastic yield reference
1,620 kip-ft
2,702.109 kip-ft
60%
Compression element compactness
Element
λ
λₚ
λᵣ
Class
Flange
8
9.152
16.178
Compact
Web
172.8
90.553
137.274
Slender
Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.
Worked solution at the starting values
Locate the elastic centroid 27.75 in above the bottom. Calculate Iₓ = 17,590.5 in⁴ using parallel axes.
Locate the plastic neutral axis 27.75 in above the bottom and integrate Zₓ = 720.563 in³.
Screen the compression elements. The flange is compact and the web is slender.
Calculation basis
The yield utilization is a reference ceiling. Verify Chapter F local buckling and LTB, shear, welds, stiffeners, and fabrication before sizing a member.
Elastic properties
Decompose the section into rectangular plates with uniform density. Use area-weighted ȳ and the parallel-axis theorem for Iₓ and Iᵧ. Divide Iₓ by the distance to each extreme fiber for Sₓ,top and Sₓ,bot; r = √(I/A).
Plastic neutral axis
Locate the equal-area axis from the bottom by integrating across each plate width. Integrate the first moment of area on both sides of that axis for Zₓ. Unit weight uses 490 lb/ft³ steel density.
Local buckling screen
B4.1b Cases 11, 15, and 16 apply to the selected compression side of a welded I-girder. Cases 19 and 21 apply to a welded box. Check the width/thickness ratio against λₚ and λᵣ. The load comparison uses FᵧZₓ as a reference, with 0.90 or 1/1.67 applied for the selected method.