SteelBeamLab

Thin-web I-girder compactness screen

Increase the clear web height and reduce thickness. The web can be slender even when the selected compression flange is compact.

Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.

ANSI/AISC 360-22B4.1b
Design method
Units

Inputs

LRFD

Use loads and strengths from the selected method. Re-enter values after switching methods.

Section and load
I-girder plates

Section and neutral axes

Yield reference
Gross area
34.875in²
Inertia Iₓ
17,590.5in⁴
Plastic Zₓ
720.563in³
Unit weight
118.672lb/ft
Section and neutral axesThe ENA is the elastic centroidal axis. The PNA divides the area in half for uniform material. The lines coincide in symmetric sections.Built-up I-sectionView from endDepth 55.5 inENA = PNALRFD yield reference59.95%0%100% limit140%+
The ENA is the elastic centroidal axis. The PNA divides the area in half for uniform material. The lines coincide in symmetric sections.

Calculation results

Limit stateDemandReferenceUse
Plastic yield reference1,620 kip-ft2,702.109 kip-ft60%

Compression element compactness

ElementλλₚλᵣClass
Flange89.15216.178Compact
Web172.890.553137.274Slender

Calculation values

ENA above bottom
27.75 in
PNA above bottom
27.75 in
Inertia Iᵧ
216.137 in⁴
Elastic Sₓ,top
633.892 in³
Elastic Sₓ,bot
633.892 in³
Radius of gyration rₓ
22.459 in
Radius of gyration rᵧ
2.489 in
First yield Mᵧ
2,641.216 kip-ft
Plastic Mₚ
3,002.344 kip-ft
Yield reference · LRFD
2,702.109 kip-ft
Yield reference · ASD
1,797.811 kip-ft

Worked solution at the starting values

  1. Locate the elastic centroid 27.75 in above the bottom. Calculate Iₓ = 17,590.5 in⁴ using parallel axes.
  2. Locate the plastic neutral axis 27.75 in above the bottom and integrate Zₓ = 720.563 in³.
  3. Screen the compression elements. The flange is compact and the web is slender.

Calculation basis

The yield utilization is a reference ceiling. Verify Chapter F local buckling and LTB, shear, welds, stiffeners, and fabrication before sizing a member.

Elastic properties

Decompose the section into rectangular plates with uniform density. Use area-weighted ȳ and the parallel-axis theorem for Iₓ and Iᵧ. Divide Iₓ by the distance to each extreme fiber for Sₓ,top and Sₓ,bot; r = √(I/A).

Plastic neutral axis

Locate the equal-area axis from the bottom by integrating across each plate width. Integrate the first moment of area on both sides of that axis for Zₓ. Unit weight uses 490 lb/ft³ steel density.

Local buckling screen

B4.1b Cases 11, 15, and 16 apply to the selected compression side of a welded I-girder. Cases 19 and 21 apply to a welded box. Check the width/thickness ratio against λₚ and λᵣ. The load comparison uses FᵧZₓ as a reference, with 0.90 or 1/1.67 applied for the selected method.

References and units ↗

More worked examples