SteelBeamLab

Welded rectangular box section in SI

Use unequal flange and side thicknesses. The offset side walls contribute strongly to the weak-axis inertia.

Preliminary structural screening. A licensed SE/PE must review results against the complete project specifications.

ANSI/AISC 360-22B4.1b
Design method
Units

Inputs

LRFD

Use loads and strengths from the selected method. Re-enter values after switching methods.

Section and load
Box plates

Section and neutral axes

Yield reference
Gross area
33,628.965mm²
Inertia Iₓ
1.84e9mm⁴
Plastic Zₓ
7.16e6mm³
Unit weight
263.955kg/m
Section and neutral axesThe ENA is the elastic centroidal axis. The PNA divides the area in half for uniform material. The lines coincide in symmetric sections.Welded boxView from endDepth 609.6 mmENA = PNALRFD yield reference86.61%0%100% limit140%+
The ENA is the elastic centroidal axis. The PNA divides the area in half for uniform material. The lines coincide in symmetric sections.

Calculation results

Limit stateDemandReferenceUse
Plastic yield reference1,925.261 kN·m2,222.879 kN·m86.6%

Compression element compactness

ElementλλₚλᵣClass
Flange19.66726.97335.884Compact
Web3658.281137.274Compact

Calculation values

ENA above bottom
304.8 mm
PNA above bottom
304.8 mm
Inertia Iᵧ
9.05e8 mm⁴
Elastic Sₓ,top
6.05e6 mm³
Elastic Sₓ,bot
6.05e6 mm³
Radius of gyration rₓ
234.187 mm
Radius of gyration rᵧ
164.076 mm
First yield Mᵧ
2,085.993 kN·m
Plastic Mₚ
2,469.866 kN·m
Yield reference · LRFD
2,222.879 kN·m
Yield reference · ASD
1,478.962 kN·m

Worked solution at the starting values

  1. Locate the elastic centroid 304.8 mm above the bottom. Calculate Iₓ = 1.84e9 mm⁴ using parallel axes.
  2. Locate the plastic neutral axis 304.8 mm above the bottom and integrate Zₓ = 7.16e6 mm³.
  3. Screen the compression elements. The flange is compact and the web is compact.

Calculation basis

The yield utilization is a reference ceiling. Verify Chapter F local buckling and LTB, shear, welds, stiffeners, and fabrication before sizing a member.

Elastic properties

Decompose the section into rectangular plates with uniform density. Use area-weighted ȳ and the parallel-axis theorem for Iₓ and Iᵧ. Divide Iₓ by the distance to each extreme fiber for Sₓ,top and Sₓ,bot; r = √(I/A).

Plastic neutral axis

Locate the equal-area axis from the bottom by integrating across each plate width. Integrate the first moment of area on both sides of that axis for Zₓ. Unit weight uses 490 lb/ft³ steel density.

Local buckling screen

B4.1b Cases 11, 15, and 16 apply to the selected compression side of a welded I-girder. Cases 19 and 21 apply to a welded box. Check the width/thickness ratio against λₚ and λᵣ. The load comparison uses FᵧZₓ as a reference, with 0.90 or 1/1.67 applied for the selected method.

References and units ↗

More worked examples