Controls & protection
Detention Pond Storage & Outlet Calculator
Screen required storage for a selected storm, then compare it with pond geometry and the orifice and weir rating.
Inputs
Detention hydrograph
Live resultsOutlet rating above release limit
Checks use the selected storm duration and report the outlet rating at the entered water depth.
Calculation results
- Storage req.
- 0.738 acre-ft
- Basin volume
- 0.888 acre-ft
- Outlet rating
- 4.75 cfs
- Storage reserve
- 0.151 acre-ft
- Inflow volume
- 0.967 acre-ft
- Storage peak time
- 65.69 min
- Inflow ends
- 74 min
- Orifice discharge
- 3.56 cfs
- Weir discharge
- 1.19 cfs
- Head above orifice center
- 4.2 ft
- Head above weir crest
- 0.2 ft
- Release rate reserve
- -0.25 cfs
Method and assumptions
Vreq = 60[Qin(tᵈ + t꜀/4) − Qout(tᵈ/2 + 3t꜀/4)] · Full orifice Qor = CᵈA√(2gh) · Qw = CʷLh³ᐟ².
The hydrograph assumes tᵈ ≥ t꜀, a 1.5 t꜀ recession and a linear release rising limb. Storage is set to zero when the allowable rate already meets the inflow peak. Test multiple IDF durations to find the controlling one. The steady-flow rating uses the EPA SWMM equivalent weir for a partly wetted side orifice and centerline head for a full opening. Downstream submergence and dynamic routing require a separate analysis.
Worked examples
Detention Pond Storage & Outlet Calculator
Inputs
- Post-development inflow
- 13 cfs
- Allowable release
- 4.5 cfs
- Storm duration tᵈ
- 50 min
- Time of concentration t꜀
- 16 min
- Bottom length
- 90 ft
- Bottom width
- 58 ft
- Water depth above bottom
- 5 ft
- Side slope z (H:V)
- 3
- Orifice diameter
- 8 in
- Orifice coefficient Cᵈ
- 0.62
- Orifice center above bottom
- 0.8 ft
- Weir crest length
- 4 ft
- Weir coefficient Cʷ
- 3.33 ft½/s
- Weir crest above bottom
- 4.8 ft
Results
- Storage req.
- 0.738 acre-ft
- Basin volume
- 0.888 acre-ft
- Outlet rating
- 4.75 cfs
- Storage reserve
- 0.151 acre-ft
- Inflow volume
- 0.967 acre-ft
- Storage peak time
- 65.69 min
- Inflow ends
- 74 min
- Orifice discharge
- 3.56 cfs
- Weir discharge
- 1.19 cfs
- Head above orifice center
- 4.2 ft
- Head above weir crest
- 0.2 ft
- Release rate reserve
- -0.25 cfs
Outlet rating above release limit
Checks use the selected storm duration and report the outlet rating at the entered water depth.
Vreq = 60[Qin(tᵈ + t꜀/4) − Qout(tᵈ/2 + 3t꜀/4)] · Full orifice Qor = CᵈA√(2gh) · Qw = CʷLh³ᐟ².
Screening worksheet · Verify design using project criteria and site data.