Worked example · Controls & protection

Orifice-only low-stage outlet rating

A circular outlet controls release near the bottom of a compact detention basin. The overflow crest sits above the modeled stage.

Inputs

Design hydrograph
0–2,000 cfs
0–2,000 cfs
1–1,440 min
1–360 min
Basin storage
1–2,000 ft
1–2,000 ft
0–70 ft
0–12

Bottom dimensions define a rectangle. All four sides have the same slope.

Outlet rating
0–120 in
0.1–1
0–70 ft
0–150 ft
0.5–6 ft½/s
0–70 ft

Use a free side outlet with its lower edge at or above the basin bottom. Set the diameter or crest length to zero to omit it.

Detention hydrograph

Live results
Detention hydrograph Storage and release checks met. Checks use the selected storm duration and report the outlet rating at the entered water depth. STORAGE REQ. 0.375 acre-ft BASIN VOLUME 0.516 acre-ft OUTLET RATING 2.14 cfs STORAGE LEFT 0.141 acre-ft Q · cfsPeak 7.8 cfs068 minInflowRelease 0Required storage2× required

Storage and release checks met

Checks use the selected storm duration and report the outlet rating at the entered water depth.

Calculation results

Storage req.
0.375 acre-ft
Basin volume
0.516 acre-ft
Outlet rating
2.14 cfs
Storage reserve
0.141 acre-ft
Inflow volume
0.524 acre-ft
Storage peak time
58.27 min
Inflow ends
67.5 min
Orifice discharge
2.14 cfs
Weir discharge
0 cfs
Head above orifice center
2.6 ft
Head above weir crest
0 ft
Release rate reserve
1.06 cfs

Stage and outlet ratings

StageftStorageft³OrificecfsWeircfsTotalcfs
0.834,6150.4300.43
1.659,8761.301.3
2.4715.82K1.7701.77
3.322.49K2.1402.14

Worked calculation

At the selected depth only the orifice contributes. Raise the stage above the crest to observe the separate weir contribution.

Vreq = 60[Qin(tᵈ + t꜀/4) − Qout(tᵈ/2 + 3t꜀/4)] · Full orifice Qor = CᵈA√(2gh) · Qw = CʷLh³ᐟ².

The hydrograph assumes tᵈ ≥ t꜀, a 1.5 t꜀ recession and a linear release rising limb. Storage is set to zero when the allowable rate already meets the inflow peak. Test multiple IDF durations to find the controlling one. The steady-flow rating uses the EPA SWMM equivalent weir for a partly wetted side orifice and centerline head for a full opening. Downstream submergence and dynamic routing require a separate analysis.

Open the main calculator

Share this calculation

This link opens the worksheet with your current inputs and units.