Controls & protection

Detention Pond Storage & Outlet Calculator

Screen required storage for a selected storm, then compare it with pond geometry and the orifice and weir rating.

Inputs

Design hydrograph
0–2,000 cfs
0–2,000 cfs
1–1,440 min
1–360 min
Basin storage
1–2,000 ft
1–2,000 ft
0–70 ft
0–12

Bottom dimensions define a rectangle. All four sides have the same slope.

Outlet rating
0–120 in
0.1–1
0–70 ft
0–150 ft
0.5–6 ft½/s
0–70 ft

Use a free side outlet with its lower edge at or above the basin bottom. Set the diameter or crest length to zero to omit it.

Detention hydrograph

Live results
Detention hydrograph Outlet rating above release limit. Checks use the selected storm duration and report the outlet rating at the entered water depth. STORAGE REQ. 0.738 acre-ft BASIN VOLUME 0.888 acre-ft OUTLET RATING 4.75 cfs STORAGE LEFT 0.151 acre-ft Q · cfsPeak 13 cfs074 minInflowRelease 0Required storage2× required

Outlet rating above release limit

Checks use the selected storm duration and report the outlet rating at the entered water depth.

Calculation results

Storage req.
0.738 acre-ft
Basin volume
0.888 acre-ft
Outlet rating
4.75 cfs
Storage reserve
0.151 acre-ft
Inflow volume
0.967 acre-ft
Storage peak time
65.69 min
Inflow ends
74 min
Orifice discharge
3.56 cfs
Weir discharge
1.19 cfs
Head above orifice center
4.2 ft
Head above weir crest
0.2 ft
Release rate reserve
-0.25 cfs

Stage and outlet ratings

StageftStorageft³OrificecfsWeircfsTotalcfs
1.257,2421.1601.16
2.516.01K2.2602.26
3.7526.45K2.9802.98
538.7K3.561.194.75

Method and assumptions

Vreq = 60[Qin(tᵈ + t꜀/4) − Qout(tᵈ/2 + 3t꜀/4)] · Full orifice Qor = CᵈA√(2gh) · Qw = CʷLh³ᐟ².

The hydrograph assumes tᵈ ≥ t꜀, a 1.5 t꜀ recession and a linear release rising limb. Storage is set to zero when the allowable rate already meets the inflow peak. Test multiple IDF durations to find the controlling one. The steady-flow rating uses the EPA SWMM equivalent weir for a partly wetted side orifice and centerline head for a full opening. Downstream submergence and dynamic routing require a separate analysis.

Share this calculation