Worked example · Conveyance
Grass-lined roadside swale
A roadside grass swale carries shallow flow along a mild grade with room for broad banks.
Inputs
Swale cross section
Live resultsWithin average lining shear
Subcritical. Compare local bed and bend shear against lining guidance.
Calculation results
- Discharge
- 10.53 cfs
- Velocity
- 2.04 ft/s
- Froude no.
- 0.49
- Avg. shear
- 0.211 lb/ft²
- Hydraulic radius
- 0.52 ft
- Flow area
- 5.16 ft²
- Water surface width
- 9.74 ft
- Wetted perimeter
- 9.93 ft
- Hydraulic depth A/T
- 0.53 ft
- Flow regime
- Subcritical
- Depth-based bed shear
- 0.316 lb/ft²
- Average shear reserve
- 0.889 lb/ft²
Worked calculation
Increase the depth and track both discharge and average lining shear. If the shear limit gets close, check local bed shear as well.
A = y(b + zy) · R = A/P · Q = K A R²ᐟ³ S¹ᐟ²/n · Fr = V/√(gA/T) · τavg = γRS.
Assumes steady uniform flow and a straight channel. The comparison uses average boundary shear. The depth-based bed shear is shown separately. HEC-15 lining design also evaluates local maximum shear, bends and steep grades.
More worked examples
Open the main calculatorGrass-lined roadside swale
Inputs
- Bottom width b
- 3.5 ft
- Side slope z (H:V)
- 4
- Flow depth y
- 0.78 ft
- Longitudinal grade
- 0.65 %
- Manning n
- 0.038
- Permissible shear
- 1.1 lb/ft²
Results
- Discharge
- 10.53 cfs
- Velocity
- 2.04 ft/s
- Froude no.
- 0.49
- Avg. shear
- 0.211 lb/ft²
- Hydraulic radius
- 0.52 ft
- Flow area
- 5.16 ft²
- Water surface width
- 9.74 ft
- Wetted perimeter
- 9.93 ft
- Hydraulic depth A/T
- 0.53 ft
- Flow regime
- Subcritical
- Depth-based bed shear
- 0.316 lb/ft²
- Average shear reserve
- 0.889 lb/ft²
Within average lining shear
Subcritical. Compare local bed and bend shear against lining guidance.
A = y(b + zy) · R = A/P · Q = K A R²ᐟ³ S¹ᐟ²/n · Fr = V/√(gA/T) · τavg = γRS.
Screening worksheet · Verify design using project criteria and site data.