Worked example · Conveyance

Shallow turf waterway

A broad, shallow turf waterway spreads a small flow across a long grassy slope.

Inputs

Channel section
0–100 ft
0–12
0–30 ft

Use equal side slopes on both banks. A zero bottom width models a V-section.

Slope and lining
0–20 %
0.008–0.2
0.01–50 lb/ft²

Use the permissible shear for the actual lining and installation.

Swale cross section

Live results
Swale cross section Within average lining shear. Subcritical. Compare local bed and bend shear against lining guidance. DISCHARGE 2.99 cfs VELOCITY 0.82 ft/s FROUDE NO. 0.24 AVG. SHEAR 0.054 lb/ft² yb · 7.4 ftz = 3:1y · 0.42 ft 0Lining limit2× limit

Within average lining shear

Subcritical. Compare local bed and bend shear against lining guidance.

Calculation results

Discharge
2.99 cfs
Velocity
0.82 ft/s
Froude no.
0.24
Avg. shear
0.054 lb/ft²
Hydraulic radius
0.362 ft
Flow area
3.64 ft²
Water surface width
9.92 ft
Wetted perimeter
10.06 ft
Hydraulic depth A/T
0.367 ft
Flow regime
Subcritical
Depth-based bed shear
0.063 lb/ft²
Average shear reserve
0.646 lb/ft²

Worked calculation

Compare the low velocity with the lining margin. A low average stress can coexist with a wide water surface.

A = y(b + zy) · R = A/P · Q = K A R²ᐟ³ S¹ᐟ²/n · Fr = V/√(gA/T) · τavg = γRS.

Assumes steady uniform flow and a straight channel. The comparison uses average boundary shear. The depth-based bed shear is shown separately. HEC-15 lining design also evaluates local maximum shear, bends and steep grades.

Open the main calculator