Worked example · Conveyance
Triangular highway median ditch
A narrow V-bottom median ditch uses equal side slopes and no flat bottom.
Inputs
Swale cross section
Live resultsWithin average lining shear
Subcritical. Compare local bed and bend shear against lining guidance.
Calculation results
- Discharge
- 15.21 cfs
- Velocity
- 2.11 ft/s
- Froude no.
- 0.48
- Avg. shear
- 0.154 lb/ft²
- Hydraulic radius
- 0.588 ft
- Flow area
- 7.2 ft²
- Water surface width
- 12 ft
- Wetted perimeter
- 12.24 ft
- Hydraulic depth A/T
- 0.6 ft
- Flow regime
- Subcritical
- Depth-based bed shear
- 0.314 lb/ft²
- Average shear reserve
- 0.746 lb/ft²
Worked calculation
The section still carries flow with b = 0 because the banks supply the area. Increase z to see the effect on top width.
A = y(b + zy) · R = A/P · Q = K A R²ᐟ³ S¹ᐟ²/n · Fr = V/√(gA/T) · τavg = γRS.
Assumes steady uniform flow and a straight channel. The comparison uses average boundary shear. The depth-based bed shear is shown separately. HEC-15 lining design also evaluates local maximum shear, bends and steep grades.
More worked examples
Open the main calculatorTriangular highway median ditch
Inputs
- Bottom width b
- 0 ft
- Side slope z (H:V)
- 5
- Flow depth y
- 1.2 ft
- Longitudinal grade
- 0.42 %
- Manning n
- 0.032
- Permissible shear
- 0.9 lb/ft²
Results
- Discharge
- 15.21 cfs
- Velocity
- 2.11 ft/s
- Froude no.
- 0.48
- Avg. shear
- 0.154 lb/ft²
- Hydraulic radius
- 0.588 ft
- Flow area
- 7.2 ft²
- Water surface width
- 12 ft
- Wetted perimeter
- 12.24 ft
- Hydraulic depth A/T
- 0.6 ft
- Flow regime
- Subcritical
- Depth-based bed shear
- 0.314 lb/ft²
- Average shear reserve
- 0.746 lb/ft²
Within average lining shear
Subcritical. Compare local bed and bend shear against lining guidance.
A = y(b + zy) · R = A/P · Q = K A R²ᐟ³ S¹ᐟ²/n · Fr = V/√(gA/T) · τavg = γRS.
Screening worksheet · Verify design using project criteria and site data.